ALDE HEATING - QUICK START GUIDE
Setup Standby Screen for bedtime
The backlight on the Standby Screen can be
disturbing if the control panel is visible from
your bed. It can be inverted for white text on
black background.
1.
Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2.
Press down arrow, until Backlight button is
displayed.
3.
Press Backlight button, select Inverted to
proceed.
>
Setup Antimicrobial function
To actively kill
Legionella
, setup the
Antimicrobial function. At 2:00 every night,
the hot water will be heated to over 65
°
C for
30 mins. This further reduces the risk of
Legionella
.
1.
Press Tool button to access the Settings
Menu (bottom right in Main Menu).
2.
Press down arrow, until Antimicrobial button
is displayed.
3.
Press Antimicrobial button to proceed.
TROUBLE SHOOTING
Any error messages will be displayed on the
Standby Screen. Error messages can be
cleared by switching off 12 V supply to the
boiler for 10 secs.
The system is completely dead, the
control panel is blank
•
Check the 20 mm T3.15 Amp glass fuse in
the boiler. This is located under the lid of the
black plastic service hatch, in a green
plastic fuse holder.
•
Check the 12 V supply to the boiler, it
should be above 12 V.
•
Check the 12 V cable is plugged into the
boiler. Check the cable is plugged into the
Alde control panel.
The boiler will not ignite on gas, but no
error message
•
The system may not need to use gas
heating if also using electric heating.
•
The fluids in the boiler may already be at
operating temperature.
The boiler will not heat on 230 V electric
•
Check the circuit breaker and any 230 V
fuses.
•
Check that any 230 V fused spurs are on
(they will often have an LED indicator and
230 V fuse).
•
Check the 230 V supply (also indicated on
the Standby Screen).
•
The fluids in the boiler may already be at
operating temperature.
No hot water
•
Check that Hot Water Ignore is not
activated on the Alde control panel.
•
Check that Continuous pumping is not
activated on the Alde control panel.
•
Check for other conflicting settings on the
Alde control panel or restore factory
defaults.
•
Check the water pump and cold water
supply to the boiler.
No central heating
•
Bleed the system of air.
•
Check the fluid level in the expansion tank.
•
Check that the circulation pump is
responding.
•
Check that hot water boost is not activated
on the Alde control panel.
•
If electric heating is not being used, set it to
"Off' on the Alde control panel.
•
Use gas and electric heating for best
performance.
•
Check that top and bottom vents in the
furniture are not obstructed.
•
Check the condition of the heat transfer
fluid.
>
Summary of Contents for ALARIA 2018
Page 14: ...PREPARING FOR THE ROAD 14 Fig 6 Checking Left Right Friction Pads...
Page 18: ...PREPARING FOR THE ROAD 18 Fig 5 Fig 6 Fig 9 Fig 8 Fig 7 Fig 10...
Page 46: ...ON THE ROAD 46...
Page 51: ...51 SERVICES SERVICES Water 52 Gas 59 Electricity 64...
Page 66: ...SERVICES 66...
Page 67: ...67 ELECTRICS ELECTRICS Power Control System 68 Battery 74 Fuses 78 Technical Data 85...
Page 86: ...ELECTRICS 86...
Page 118: ...118 FLYSCREENS BLINDS ROOFLIGHTS Opening and closing the panoramic rooflight...
Page 126: ...126...
Page 127: ...127 AL KO CHASSIS TYRES AL KO CHASSIS TYRES Chassis 128 General Maintenance 129 Tyres 130...
Page 132: ...GENERAL DATA 132 ALARIA...
Page 133: ...133 GENERAL DATA ALARIA...
Page 134: ...GENERAL DATA 134 ALARIA...
Page 135: ...135 GENERAL DATA ALARIA...
Page 136: ...GENERAL DATA 136 ALARIA...
Page 137: ...137 GENERAL DATA ALARIA...
Page 144: ...GENERAL DATA 144...