ALDE HEATING - QUICK START GUIDE
MAIN MENU
Press MENU button to access the Main Menu
from the Standby Screen or Settings Menu.
The screen will revert to the Standby Screen
after 30 secs if untouched.
1.
Standby Screen. Press MENU button.
2.
Main Menu.
a.
What’s Activated Menu. [Not displayed
if no activated functions are detected.]
b.
Settings Menu
Desired Room Temperature
The desired room temperature can be
set from 5 to 30
°
C, in 0.5 increments.
Tip!
The World Health Organisation
recommends a room temperature of
18–24
°
C for healthy living.
NB:
If Day or Night Mode are active, the
temperature cannot be adjusted, the Plus and
Minus buttons will be greyed out.
1.
The current desired room temperature is
displayed.
2.
Adjust by pressing Plus or Minus button.
Domestic Hot Water
The Alde boiler stores 8.4 Litres of hot
water as standard. If the hot water
cylinder is empty, the air is heated but
no damage can result.
Tip!
In a good summer, for example, lower
the desired temperature on the control panel
to around 10
°
C. The central heating will not
circulate (unless the temperature drops to
10
°
C), but you can still control hot water.
NB:
If Day or Night Mode Sans Hot Water
are active, the hot water cannot be adjusted,
the Plus and Minus buttons will be greyed
out.
1. Hot Water Ignore. Volume bar empty. No
attempt is made to heat hot water
specifically. This saves energy when the
freshwater is drained down.
2. Hot Water Normal. Volume bar half-full.
Hot water is heated to greater than 50
°
C.
NB: If Circulation Pump is set to
Continuous, this option will not be
available.
3. Hot Water Boost. Volume bar full. Central
heating circulation is disabled for 30
mins. Hot water is heated to greater than
65
°
C. After 30 mins the system reverts to
Hot Water Normal.
4. Adjust by pressing Plus or Minus button.
Electric Heating
Check that 230V supply is displayed
on the Standby Screen. The Alde
boiler is programmed to use power
economically and there are times
when it may use no power at all, even
if set to 3 kW.
1.
Select Off, 1, 2 or 3 kW electric heating.
More power equals better performance, but
may be restricted by the current (amps) limit
on the electric hook-up.
2.
Adjust by pressing Plus or Minus button.
Max current draw from 230 V supply is 4.5 A
on 1 kW, 9 A on 2 kW, 14 A on 3 kW. If the
electric supply has unstable voltage, the
amperage will also fluctuate.
Gas Heating
The Alde boiler is programmed to use
power economically. The gas burner
has two stages, shifting dynamically
between low or full flame. There are
times when it may use no power at
all, even if gas heating is selected.
1.
Press the Flame button to select gas
heating. Green is on, blue is off.
Use both gas and electric heating for best
performance.
Summary of Contents for ALARIA 2018
Page 14: ...PREPARING FOR THE ROAD 14 Fig 6 Checking Left Right Friction Pads...
Page 18: ...PREPARING FOR THE ROAD 18 Fig 5 Fig 6 Fig 9 Fig 8 Fig 7 Fig 10...
Page 46: ...ON THE ROAD 46...
Page 51: ...51 SERVICES SERVICES Water 52 Gas 59 Electricity 64...
Page 66: ...SERVICES 66...
Page 67: ...67 ELECTRICS ELECTRICS Power Control System 68 Battery 74 Fuses 78 Technical Data 85...
Page 86: ...ELECTRICS 86...
Page 118: ...118 FLYSCREENS BLINDS ROOFLIGHTS Opening and closing the panoramic rooflight...
Page 126: ...126...
Page 127: ...127 AL KO CHASSIS TYRES AL KO CHASSIS TYRES Chassis 128 General Maintenance 129 Tyres 130...
Page 132: ...GENERAL DATA 132 ALARIA...
Page 133: ...133 GENERAL DATA ALARIA...
Page 134: ...GENERAL DATA 134 ALARIA...
Page 135: ...135 GENERAL DATA ALARIA...
Page 136: ...GENERAL DATA 136 ALARIA...
Page 137: ...137 GENERAL DATA ALARIA...
Page 144: ...GENERAL DATA 144...