Reverse Module Installation (Continued)

2.5: For Ceiling Fan Model CF2400 ONLY.

14. Locate the Capacitor Gray Wire which is 

connected to the Gray Wire coming from the 

Center of the Motor (yellow wire on older 

models) (Figure 5). 

15. Remove the Wire Connector and separate these 

Wires. 

16. Cap the Gray Wire coming from the Motor using 

a Wire Connector (supplied) (Figure 5).

CF2400 - INSTALL WIRE 

CONNECTOR ON GRAY 

WIRE

(

CF1 & CF2800 - YELLOW  

WIRE

)

CF2400 GRAY WIRE 

(

YELLOW WIRE ON 

NEWER MODELS

)

CAPACITOR 

GRAY WIRE

CAPACITOR

  Figure 5

SWITCH 

HOUSING

REMOVE 

CAPACITOR/ 

WIRING HARNESS/ 

SWITCH(ES)

FROM SWITCH 

HOUSING

  Figure 6

2.6: All Ceiling Fan Models.

17. Separate the Capacitor (held in place with 

two-sided tape) from the Switch Housing 

(Figure 6).

18. Remove the Wiring Harness and Switch(es) 

from the Switch Housing.

NOTE: Keep the wiring harness if you think you may 

like to return to manual control in the future.

SWITCH 

HOUSING

RECTANGULAR PLUG

PULL CHAIN 

SWITCH PLUGS

  Figure 7

2.7: All Ceiling Fan Models.

If Not Already Completed:

19. Close the Hole(s) for the Speed Control Switch, 

the Uplight Switch, and the Reverse Switch 

by installing Pull Chain Plug(s) (supplied) 

or Rectangular Plug (supplied) in the Hole(s) 

(Figure 7). 

 

Choose the color that best matches your Ceiling 

Fan.

Summary of Contents for RCK55

Page 1: ...Owner s Manual carefully before installing the Receiver Retain Owner s Manual for future reference 2 Make certain no bare wires are exposed outside the wire connectors 3 All wiring must be in accorda...

Page 2: ...sing Figure 1 2 All Ceiling Fan Models Disconnect the Motor Connector from the Wiring Harness Connector Figure 1 3 Unscrew the Knurled Nut securing the Speed Control Switch to the Switch Housing Figur...

Page 3: ...CUT THE YELLOW WIRE AND CAP USING WIRE CONNECTOR SEPARATE BLUE WIRE COMING FROM CEILING FAN AND CAP USING WIRE CONNECTOR 2 REMOVE WIRE CONNECTOR SECURING THREE BLUE WIRES 1 3 KNURLED NUT Figure 2 NOT...

Page 4: ...SWITCH HOUSING REMOVE CAPACITOR WIRING HARNESS SWITCH ES FROM SWITCH HOUSING Figure 6 2 6 All Ceiling Fan Models 17 Separate the Capacitor held in place with two sided tape from the Switch Housing Fi...

Page 5: ...re 9 2 9 All Ceiling Fan Models 23 Using a Wire Connector supplied connect the Motor White Wire to the Reverse Module White Wire Figure 9 24 Using a Wire Connector supplied connect the Motor Blue Wire...

Page 6: ...t and unkink the 80 Fan Yellow Wire supplied with the fan and cut off the Connector from the end of the Wire 30 Strip 1 2 inch of Insulation from the end of this Wire Then join the 80 Fan Yellow Wire...

Page 7: ...rands Substitution of parts or accessories not designated for use with this product by Luminance Brands could result in personal injury or property damage WARNING SUPPLY GROUND WIRE GREEN OR BARE HANG...

Page 8: ...E WIRE RECEIVER WHITE WIRE AC IN MOTOR N Figure 16 FAN BLACK WIRE RECEIVER BLACK WIRE TO MOTOR L Figure 17 3 4 6 Securely connect the Receiver Black Wire TO MOTOR L to the Fan Black Wire using the Wir...

Page 9: ...Yellow Wire and strip back insulation 1 2 from the end of the Wire 11 Securely connect the Receiver Yellow Wire UPPER LIGHT to the Fan Yellow Wire using the Wire Connector supplied in parts bag Figure...

Page 10: ...TH LOCKWASHER 2 1 1 4 THREADED STUD 2 8 32 KNURLED KNOB 2 Figure 22 WHITE SUPPLY WIRE BLACK FAN WIRE RECEIVER TO 110V SUPPLY LISTED GENERAL USE ON OFF WALL SWITCH OR OPTIONAL SW605 WALL CONTROL YELLOW...

Page 11: ...the Fan is set to HIGH Speed Check that the Pull Chain Speed Switch is ON Check that the Battery is good indicator light should light when any button is pressed Check that the Receiver is wired prope...

Page 12: ...ance Brands Ceiling Fan Product motor or any Luminance Brands Ceiling Fan Product component or Luminance Brands Ceiling Fan Product accessory caused by normal wear and tear rather than due to defects...

Reviews: