background image

7

luminancebrands.com

Please contact 1-800-777-4440 for further assistance

Model No.: RCK55

Receiver Installation

If you feel that you do not have enough electrical 

wiring knowledge or experience, have your fan 

installed by a licensed electrician.

To avoid possible electrical shock, be sure 

electricity is turned off at the main fuse box or 

circuit breaker panel before wiring.
NOTE: If you are not sure if the outlet box is 

grounded, contact a licensed electrician for 

advice, as it must be grounded for safe operation.

 

WARNING

!

To reduce the risk of electrical shock, disconnect 

the electrical supply circuit before installing the 

fan, light kit or receiver.

 

CAUTION

!

Disconnect Electrical Power to the Branch Circuit at 

the Circuit Breaker Panel or Main Fuse Box before 

attempting to Wire the Ceiling Fan.

Turning off wall switch is not sufficient. 

To avoid possible electrical shock, be sure 

electricity is turned off at the main fuse 

box or circuit breaker panel before wiring. 

All wiring must be in accordance with National 

and Local codes and the ceiling fan must be 

properly grounded as a precaution against 

possible electrical shock.

 

WARNING

!

This product is designed to use only those 

parts supplied with this product and/or any 

accessories designated specifically for use 

with this product by Luminance Brands. 

Substitution of parts or accessories not 

designated for use with this product by 

Luminance Brands could result in personal 

injury or property damage.

 

WARNING

!

SUPPLY GROUND

WIRE

(GREEN OR BARE)

HANGER BALL

GROUND WIRE

(GREEN)

HANGER BRACKET

GROUND WIRE

(GREEN)

RECEIVER 

NOTCH

CEILING 

COVER

OPEN SIDE OF 

HANGER 

BRACKET

SIDE OF

HANGER 

BRACKET

  Figure 14

3.1

1. Pull the Ceiling Fan Downrod Wires and the 

Supply Wires through the open side of the Hanger 

Bracket.

2. Position the RCK55 Receiver in the Ceiling Cover 

so that the flat side of the Receiver faces up.  Align 

the Notch in the Receiver with the Side of the 

Hanger Bracket.  Also ensure the Receiver wires 

align with the open side of the Hanger Bracket. 

(Figure 14).

  Figure 15

3.2

NOTE: Make all wiring connections using the wire 

connectors supplied in the receiver parts bag. 

Make sure that all connections are tight, including 

ground, and that no bare wire is visible at the wire 

connectors, except for the supply circuit ground wire.

3. Connect the Hanger Ball Green Ground Wire and 

the Hanger Bracket Green Ground Wire to the 

Supply Ground Conductor (this may be a bare wire 

or wire with Green Colored insulation).

4. Securely connect Wires with Wire Connector 

(supplied in parts bag) (Figure 15).

Assemble your Ceiling Fan (including the fan blades), 

install the Hanger Bracket, and then hang the Fan in 

accordance with the instructions in the Ceiling Fan 

Owner’s Manual. Wire the Ceiling Fan and Receiver 

and complete the installation in accordance with the 

following:

Summary of Contents for RCK55

Page 1: ...Owner s Manual carefully before installing the Receiver Retain Owner s Manual for future reference 2 Make certain no bare wires are exposed outside the wire connectors 3 All wiring must be in accorda...

Page 2: ...sing Figure 1 2 All Ceiling Fan Models Disconnect the Motor Connector from the Wiring Harness Connector Figure 1 3 Unscrew the Knurled Nut securing the Speed Control Switch to the Switch Housing Figur...

Page 3: ...CUT THE YELLOW WIRE AND CAP USING WIRE CONNECTOR SEPARATE BLUE WIRE COMING FROM CEILING FAN AND CAP USING WIRE CONNECTOR 2 REMOVE WIRE CONNECTOR SECURING THREE BLUE WIRES 1 3 KNURLED NUT Figure 2 NOT...

Page 4: ...SWITCH HOUSING REMOVE CAPACITOR WIRING HARNESS SWITCH ES FROM SWITCH HOUSING Figure 6 2 6 All Ceiling Fan Models 17 Separate the Capacitor held in place with two sided tape from the Switch Housing Fi...

Page 5: ...re 9 2 9 All Ceiling Fan Models 23 Using a Wire Connector supplied connect the Motor White Wire to the Reverse Module White Wire Figure 9 24 Using a Wire Connector supplied connect the Motor Blue Wire...

Page 6: ...t and unkink the 80 Fan Yellow Wire supplied with the fan and cut off the Connector from the end of the Wire 30 Strip 1 2 inch of Insulation from the end of this Wire Then join the 80 Fan Yellow Wire...

Page 7: ...rands Substitution of parts or accessories not designated for use with this product by Luminance Brands could result in personal injury or property damage WARNING SUPPLY GROUND WIRE GREEN OR BARE HANG...

Page 8: ...E WIRE RECEIVER WHITE WIRE AC IN MOTOR N Figure 16 FAN BLACK WIRE RECEIVER BLACK WIRE TO MOTOR L Figure 17 3 4 6 Securely connect the Receiver Black Wire TO MOTOR L to the Fan Black Wire using the Wir...

Page 9: ...Yellow Wire and strip back insulation 1 2 from the end of the Wire 11 Securely connect the Receiver Yellow Wire UPPER LIGHT to the Fan Yellow Wire using the Wire Connector supplied in parts bag Figure...

Page 10: ...TH LOCKWASHER 2 1 1 4 THREADED STUD 2 8 32 KNURLED KNOB 2 Figure 22 WHITE SUPPLY WIRE BLACK FAN WIRE RECEIVER TO 110V SUPPLY LISTED GENERAL USE ON OFF WALL SWITCH OR OPTIONAL SW605 WALL CONTROL YELLOW...

Page 11: ...the Fan is set to HIGH Speed Check that the Pull Chain Speed Switch is ON Check that the Battery is good indicator light should light when any button is pressed Check that the Receiver is wired prope...

Page 12: ...ance Brands Ceiling Fan Product motor or any Luminance Brands Ceiling Fan Product component or Luminance Brands Ceiling Fan Product accessory caused by normal wear and tear rather than due to defects...

Reviews: