D. INSTALLATION AND START-UP
1. CONNECTION AND ASSEMBLY
For the PL24-COB-D-UVC model:
Inside the luminaire is the power supply unit connected to the controller and LED modules via a cable connector
(according to fig.1). Unscrew the top cover of the luminaire and install it on the ceiling surface using the included
mounting pins, so that the L and N power wires pass through the centre hole of the cover. Connect the L and N
power wires to the power supply and then gently tighten the luminaire housing to the ceiling installed lid.
For model CL24-COB-D-UVC:
Remove the power supply unit with the installed cable connector from the packaging. Remove the HULLCS24
controller from the packaging and connect the power supply connector to the controller. Connect the
WHITE+/WHITE- and UVC+/UVC- cable connectors coming out of the controller to the LED module connectors
coming out of the luminaire housing as shown in fig. 1. Cut a 195mm diameter mounting hole in the false ceiling
and route the L and N power wires to prepare them for connection to the power supply.
Connect the L and N power wires to the power supply. Place the power supply and controller on or next to the
luminaire on top of the suspended ceiling. Install the luminaire in the mounting hole using the spring-loaded
mounting brackets.
In case of the need to reconnect the wires of the power supply connector (between the controller and the power
supply, the controller and the lamp, as well as between the controller and the detector), it is absolutely necessary
to remember
that this operation may only be performed when the power supply is disconnected from the
mains power source
(
110-250V AC
). Fig. 1 shows the factory-made, correct connection diagram.
•
Before mounting the luminaires in the ceiling, it is recommended to write down the serial numbers of each
luminaire, to enable an identification of each installed luminaire loacation with particular serial number
•
To connect a wired 12V DC detector, use the following sockets on the controller: +12V DC, INPUT and GND
•
The luminaires can be switched on and off using a standard wall switch (lighting mode only)
•
When the luminaire is switched on via a wall switch, using a mobile device (e.g. smartphone), the UVC
disinfection mode can be switched on, off and the brightness of the white light can be controlled (lighting
mode)
•
Luminaires do not work with external wall dimmers (located before the power supply)
•
The luminaires meet the obligatory electromagnetic compatibility norms, however they might be vunerable
to interferences from devices which don’t meet above mentioned norms, if they are working and are
present in vicinity
Lumenmax 2021, all rights reserved ©, users manual version V1.030521