background image

IMPAC pyrometers IN 300 · IN 300/5

 

 

 

 

17 

Example for wiring using a digital display with integrated power supply: 

Controller

°C

Recorder

Digital display  
with built-in  
2-wire supply

 

230 V 

~

white 

brown

Wiring

 

white 

24 V 

brown 

0 V 

black 

Shield 

Shield (black)

4 ... 20 mA 

 

 
 

Example for wiring using an external power supply: 

Controller

°C

Recorder

Digital display

230 V 

~

4 ... 20 mA 

white 

brown 

Shield (black)

24 V DC

Power supply

Wiring

 

white 

24 V 

brown 

0 V 

black 

Shield 

 

 

 

Note:

  

Additional analyzing instruments, e.g. controllers, recorders, etc  
can be connected in series as shown in drawing above. 

 
 

4.1 

Accessories 

Numerous accessories guarantee easy installation of the pyrometers. The Following overview 
shows a selection of suitable accessories: 
 

 

 

 

 

 

   

 

 
  Mounting  

Air purges 

Water 

LED digital 

Power supplies 

  supports 

 

cooling jackets 

displays with  

C/Z 

 

   

 

 

built-in 

power 

supply 

 

 

Summary of Contents for IN 300

Page 1: ...IN 300 IN 300 5 IMPAC Pyrometer Betriebsanleitung Operation Manual Proven Quality www imaxsun com...

Page 2: ...ons 15 2 2 Appropriate use 16 2 3 Scope of delivery 16 3 Safety 16 3 1 General 16 3 2 Electrical connection 16 4 Electrical Installation 16 4 1 Accessories 17 5 Optics 18 5 1 IN 300 18 5 2 IN 300 5 18...

Page 3: ...nd experience LumaSense Technologies is not liable for any damages that arise from the use of any examples or processes mentioned in this manual or in case the content of this document should be incom...

Page 4: ...tput 4 20 mA load independent current linear to temperature Max load max 500 at 24 V max 200 at 18 V Emissivity 0 4 1 adjustable Repeatability 1 of the measuring range 1 Tamb 23 C Accuracy 1 5 of temp...

Page 5: ...connection Follow common safety regulations for mains voltage 230 or 115 V AC connecting additional devices operating with this mains voltage e g transformers Touching mains voltage can be mortal A no...

Page 6: ...C Recorder Digital display 230 V 4 20 mA white brown Shield black 24 V DC Power supply Wiring white 24 V brown 0 V black Shield Note Additional analyzing instruments e g controllers recorders etc can...

Page 7: ...the measuring distance in mm e g 300 mm in which it has the smallest spot size in relation to its measuring distance IN 300 e g 20 mm The following drawings show the size of the spots in mm in depende...

Page 8: ...is set ex works to an emissivity of 100 To adjust the emissivity factor to your own purpose you have to remove the rear cover by unscrew the locking screw Remove the cover carefully In the tube there...

Page 9: ...unction the pyrometer 8 Maintenance 8 1 Safety Attention during pyrometer services Should the pyrometer be integrated in a running machine process the machine has to be switched off and secured agains...

Page 10: ...8 2 Temperature indication too high Emissivity set too low Set lower correct emissivity corresponding to the material see 6 The measurement is influenced by reflections of hot machine parts Use mecha...

Page 11: ...DA 4000 LED display 2 wire power supply 2 limit switches relay contacts 3 890 520 DA 6000 LED display RS232 2 wire power supply maximum value storage analog output 3 890 530 DA 6000 LED display RS485...

Reviews: