background image

IMPAC pyrometers IN 300 · IN 300/5

 

 

 

 

14 

1

 

General 

 

1.1 

Information about the operation manual 

Congratulations on choosing this high quality and highly efficient IMPAC Pyrometer.  

Please read this manual carefully, step by step, including all notes to security, operation and 
maintenance before using the pyrometer. For operation of the instrument this manual is an 
important source of information and work of reference. To avoid handling errors keep this manual 
in a location where you always have access to. When operating the instrument, it is necessary to 
follow the generally safety instructions (see section 

3

,

 Safety

). 

Additionally to this manual the manuals of the components used are valid. All notes – especially 
safety notes – are to be considered.  

Should you require further assistance, please call our customer service hotline in Frankfurt, 
Germany, +49 (0)69 9 73 73-0 or Oakland, A1 201 405-0900 or call from America 800-
631-0176. 
 
 

1.2 

Limit of liability and warranty 

All general information and notes for handling, maintenance and cleaning of this instrument are 
offered according to the best of our knowledge and experience.  

LumaSense Technologies is not liable for any damages that arise from the use of any examples or 
processes mentioned in this manual or in case the content of this document should be incomplete 
or incorrect. LumaSense Technologies reserves the right to revise this document and to make 
changes from time to time in the content hereof without obligation to notify any person or persons 
of such revisions or changes. 
All series 300 Instruments from LumaSense Technologies have a warranty of two years from the 
invoice date. This warranty covers manufacturing defects and faults which arise during operation 
only if they are the result of defects caused by LumaSense Technologies.  
This warranty is void if the instrument is disassembled or modified without prior written consent 
from LumaSense Technologies. 
 
 

1.3 

Terminology 

The used terminology corresponds to the VDI- / VDE-directives 3511, page 4. 
 
 

1.4 

Copyright 

All copyrights reserved. This document may not be copied or published, in part or completely, 
without the prior written permission of LumaSense Technologies GmbH. Contraventions are liable 
to prosecution and compensation. All rights reserved. 
 
 

1.5 

Disposal / decommissioning 

Inoperable IMPAC pyrometers have to be disposed corresponding to the local regulations of 
electro or electronic material.  

 

 
 
 
 

Summary of Contents for IN 300

Page 1: ...IN 300 IN 300 5 IMPAC Pyrometer Betriebsanleitung Operation Manual Proven Quality www imaxsun com...

Page 2: ...ons 15 2 2 Appropriate use 16 2 3 Scope of delivery 16 3 Safety 16 3 1 General 16 3 2 Electrical connection 16 4 Electrical Installation 16 4 1 Accessories 17 5 Optics 18 5 1 IN 300 18 5 2 IN 300 5 18...

Page 3: ...nd experience LumaSense Technologies is not liable for any damages that arise from the use of any examples or processes mentioned in this manual or in case the content of this document should be incom...

Page 4: ...tput 4 20 mA load independent current linear to temperature Max load max 500 at 24 V max 200 at 18 V Emissivity 0 4 1 adjustable Repeatability 1 of the measuring range 1 Tamb 23 C Accuracy 1 5 of temp...

Page 5: ...connection Follow common safety regulations for mains voltage 230 or 115 V AC connecting additional devices operating with this mains voltage e g transformers Touching mains voltage can be mortal A no...

Page 6: ...C Recorder Digital display 230 V 4 20 mA white brown Shield black 24 V DC Power supply Wiring white 24 V brown 0 V black Shield Note Additional analyzing instruments e g controllers recorders etc can...

Page 7: ...the measuring distance in mm e g 300 mm in which it has the smallest spot size in relation to its measuring distance IN 300 e g 20 mm The following drawings show the size of the spots in mm in depende...

Page 8: ...is set ex works to an emissivity of 100 To adjust the emissivity factor to your own purpose you have to remove the rear cover by unscrew the locking screw Remove the cover carefully In the tube there...

Page 9: ...unction the pyrometer 8 Maintenance 8 1 Safety Attention during pyrometer services Should the pyrometer be integrated in a running machine process the machine has to be switched off and secured agains...

Page 10: ...8 2 Temperature indication too high Emissivity set too low Set lower correct emissivity corresponding to the material see 6 The measurement is influenced by reflections of hot machine parts Use mecha...

Page 11: ...DA 4000 LED display 2 wire power supply 2 limit switches relay contacts 3 890 520 DA 6000 LED display RS232 2 wire power supply maximum value storage analog output 3 890 530 DA 6000 LED display RS485...