-2-
598-1010-05
Lock Nut
CAUTION: For under eave installation, the
sensor head must be rotated as shown in the next
two steps for proper operation and to avoid the risk of
electrical shock.
❒
Swing the sensor head towards the clamp screw.
For eave mount only:
❒
Rotate the sensor head clockwise 180° so the
controls face down.
INSTALLATION
Wire the Light Control
WARNING: Turn power off at the fuse or circuit
breaker.
1. Remove the existing light fixture.
2. Install the mounting strap as shown using two screws
that fit your junction box.
3. The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.
Controls
Clamp Screw
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
Controls
Controls
Mount the Light
1. Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
2. Align the three slots in the decorative shell with the
lamp holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.
Wall Mount
Eave Mount
White to
White
Black to
Black
Junction box ground wire to
green ground screw on fixture.
Gasket
Mounting
Strap
Mounting
Bolt
Rubber
Plug
3. Push the rubber plug firmly into place.
4. If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone weather
sealant.
5. Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the
floodlamps, do not overtighten.
To avoid water damage and
electrical shock, keep lamp
holders 30° below horizontal.
Keep lamps at least
1" (2.5 cm) from the
sensor. Do not allow
the lamps to block
the lens.
Shell Slot
Lens
4. Route the light control’s wires through the large
gasket hole.
5. Twist the junction box wires and fixture wires together
as shown. Secure with a wire connector.
For easy installation, select an existing light with a wall
switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m)
above the ground.
NOTE: If fixture is mounted higher than
8 ft. (2.4 m), aiming the sensor down will reduce coverage
distance.