Appendix A Reference Information
Module Alarm Status Table
A-16
255-700-467
PacketStar
®
PSAX 4-Port Voice 2-Wire Office Module User Guide
, Issue 1
Release 9.0.0
Module Alarm Status Table
The alarm status descriptions for the Alarm Status field on the Equipment
Configuration window are provided in Table A-6.
§
The module supports PRI ISDN in DS1 and E1 modes only.
¶
European modules do not support this interface with the 8-Port Voice 2-Wire Station module or the
4-Port Voice 2-Wire Office module.
**
Port 2 only.
Table A-6. Alarm Status Descriptions for Modules on the Equipment Configuration Window
Alarm Status
Module Type
Affected
Description
NoAlarm
I/O and Server
Indicates that no alarms have been detected for the mod-
ule in this slot.
WrongCardType
I/O and Server
Indicates that one type of module was configured in this
slot in the chassis, but a now different module occupies
this slot.
LineFailed
All
Indicates that the module in this slot is no longer receiv-
ing or transmitting signals because the line failed.
Hexadecimal format,
Example:
12345678ABC
I/O and Server
Indicates that one or more ports on the module in this
slot currently have a loss of signal. The numbers indicate
which ports have a loss of signal. For modules that have
more than eight ports not receiving signals, the value in
this field is in hexadecimal format.
CardRemoved
All
Indicates that one of the following events occurred:
•
The module in this slot was configured and then
removed from the slot.
•
Connections on the OC-3, OC-12, STM-1, or STM-4
APS/MSP primary module in this slot were transferred
to the standby module. After the transfer occurs, the
former primary module then displays CardRemoved
in the Alarm Status field; the former standby module
then displays Primary in the Status field.
ReferenceClockFailed Stratum 3–4
Indicates that the timing reference clock on the Stratum
module in this slot failed.
CompositeClockFailed Stratum 3–4
Indicates that the timing composite clock on the Stratum
module in this slot failed.
Overload
Power Supply
Indicates that the Power Supply module is operating
under an overload condition.
PowerFailed
Power Supply
Indicates that the power has failed.
Minus48vFailed
Power Supply
Indicates that the -48 V dc Power Supply module output
failed.
UnknownAlarm
I/O and Server
Indicates that the reason for failure is not known.
CompleteClockFailed
Stratum 3–4
Indicates that the backplane detected a clock error.
PowerFailed
Power Supply
Indicates that no power is coming into the PSAX chassis.