
Initial System Administration
3-24
Issue 2 December 1996
The system responds with the Switch Time Zone screen.
If the time zones of your associated switches have not been defined for
your AUDIX system, only the columns of switch numbers will appear. Fill in
the table for those switches that are part of your DEFINITY
communications system network.
2. In the Time Zone column, enter a number that indicates how many time
zones west of Greenwich (England) the indicated switch is located (here,
the prime meridian introduces time zone zero, and time zone 5 is U.S.
eastern time).
3. In the Daylight Savings column, enter
y
if the indicated switch is located in
a region where daylight savings is observed (that is, where time is
adjusted by an hour in April and October to take advantage of more
sunlight). Otherwise, enter
n
in this column.
4. Press the
(F3) function key to save the changes.
NOTE:
The system will not put these changes into effect until you have
rebooted the system (the next task).
5. Proceed to Task 14J: Reboot the DEFINITY AUDIX System.
ENTER
Summary of Contents for Definity Audix System
Page 14: ...About This Document xiv Issue 2 December 1996...
Page 22: ...Prerequisites 1 8 Issue 2 December 1996...
Page 96: ...Initial System Administration 3 38 Issue 2 December 1996...
Page 170: ...Option Settings B 20 Issue 2 December 1996...