Glossary
Issue 2 December 1996
GL-3
C
Call Answer
A feature that allows the system to answer a call and record a message when the subscriber is
unavailable. Callers may be redirected to the system through the call coverage or Call Forwarding
switch features. Subscribers may record a personal greeting for these callers.
Call Answer Language Choice
Call answer multilingual option where a user can alternate between a primary language set and a
secondary language. The two languages are administered on a per subscriber basis. If this fea-
ture is enabled, the subscriber may not use the standard DEFINITY AUDIX Multiple Personal
Greetings feature.
Camp-On
A system shutdown option that waits for ports to become idle before blocking service to them.
This allows subscribers to finish calls in progress.
Central Office (CO)
A main telephone office where private customer lines are terminated and connected to the public
network through common carriers.
Central Processing Unit (CPU)
The Multifunction board’s main processor that controls system data transfer, input/output (I/O),
and logical instructions.
Class of Service (COS)
The standard set of features given to subscribers when they are first administered (set up with a
voice mailbox).
Command Mode
A system state where flashware is in control and software is shut down. In this state, a technician
has access to menu options to see flashware status and initialization history, run through flash-
ware diagnostics, and to start or continue system initialization.
Configuration
The particular composition and hardware selected for a system, including internal options and
peripheral equipment.
Control Link (CL)
The integration, or interface, between the DEFINITY AUDIX System and the switch that enables
the transmission of control messages from the DEFINITY AUDIX System to the switch over a DCIU
data link. The control messages are transmitted over a separate cable connection and carry infor-
mation such as calling-party identification and message-waiting indicator status and control.
Control-Link Mode
The type of switch-link integration for which the DEFINITY AUDIX System, R2.0 or later, is con-
nected to the switch via analog-line card emulation and a digital connection.