Issue 1 CRCS R6.0 April 1999
Appendix A: Modem Pooling
If you begin with the Async_Dial Factory default option settings, then the AT com-
mands and Diagnostic Control Panel LCD command sequences to option the
options are as shown in the following list:
n
Clear options/registers to factory default: &F0 (Configure/Factory)
n
DTR call control is enabled: &D2 (Configure/Edit/DTE Interface)
n
DSR tracks data set ready: &S1 (Configure/Edit/DTE Interface)
n
Numeric form (2) of result codes is enabled: V2 (Configure/Edit/DTE
Dialer)
n
Extended Result Codes set to Use_DTE_Rate: X7 (Configure/Edit/DTE
Dialer)
n
Long space disconnect is disabled: Y0 (Configure/Edit/Line Dialer)
n
MNP5 Compress is disabled: %C0 (Configure/Edit/V42/MNP/Buffer)
n
Dial Line Rate is set to 9600 bps: S41=3 (Configure/Edit/Dial Line)
n
Disable the AT Escape Char option: S2=128 (Configure/Edit/DTE Dialer)
n
Command echo is disabled: E0 (Configure/Edit/DTE Dialer)
n
Store option/register changes to Active(Save): &W0 (Configure/Save)
Test
DTE RL (CT140)
Disable
S51=0
DTE LL (CT141)
Disable
S52=0
Test Timeout
Disable
S18=0
Rcv Remote Loop
Enable
AT&T..
V54 Address
Disable
S53=0
V54 Device Type
Peripheral
S54=0
Misc
StrapsWhenDisc
No_Change
S88=0
Speaker Control
OnUntilCarr
ATM..
Speaker Volume
Medium
ATL..
Access frm Remt
Enable
S55=0
Dir#1_Callback
Disable
S67=0
Table 3.
3800 Series Modem Installation — Continued
Activ (Operating)
Option
Selection
AT Command