d
Verify that the terminating resistor jumpers are set to OFF, when
the set is in a point-to-point configuration and the terminating
resistor is in the closet or a 440A4 is connected on the line.
d
Verify that the terminating resistor jumpers are set to ON, when
the set is in a point-to-point configuration and the terminating
resistor is
not in the closet or a 440A4 is not connected to the
line.
d
Verify that the terminating resistor jumpers are set to OFF, when
the set is in a multipoint configuration and the terminating resistor
is either in the closet or a 440A4 is connected on the line, or the
jumper is set to ON in one of the other sets on the line. NOTE:
Only one terminating resistor is used for multipoint configuration.
d
Verify that the terminating resistor jumpers are set to ON, when
the set is in a multipoint configuration and the terminating resistor
is
not in the closet, a 440A4 is not connected on the line or, the
jumper is
not set to ON in any of the other sets on the line.
TERM. RESIST
OR
AUX
PHAN
TERM. RESIST
OR
AUX
ON
PHAN
OFF
POWER
Auxiliary Power and
Terminating Resistor OFF
ON
OFF
POWER
Auxiliary Power and
Terminating Resistor ON