Piccolo
67 from 82
www.lt-light.com
Remote unit has the same communication channels that the console (ID 5). If needed, set the same
number in both, console & remote. Now, you can take control of the console from Remote.
Consult Remote manual for more information.
37.4.7. Wireless DMX (36)
If your console has the hardwre (optional) that permits to the console “transmits” DMX by radio
frequency (2405-2479 MHz), this menu allows to connect the wireless DMX (connection between
emitter and receiver) using the following commandos:
Executing the commando
0: LOGOUT
to disconnect the RF DMX of all the active receivers;
receivers that were linked with the DMX of this console. Note: No-activated Receivers will remain
“connected”
Executing the commando
1: LOGIN
to connect the RF DMX with all the free receivers;
receivers that must be free and active during the execution of the command.
37.5. ETHERNET
37.5.1. Ethernet Configuration (40)
Check chapter ETHERNET, page-70
37.6. SPECIAL COMMANDS
37.6.1. Multimedia Panel (70)
In this menu it is possible to activate/deactivate all multimedia ports (
Midi, Ext, Sound
&
Time Code
).
37.6.2. Status & Playbacks Zero (71)
These commands are to set some parts of the console to
Zero
:
Status
: Sets to default all editing functions (
Flash
,
LN.TM
…)
All Playbacks
: Sets to
Zero
, but does not modify the Submaster outputs and the
crossfader output. These outputs can be set to Zero independently, using the commands:
All
Submasters
&
All Crossfaders
.
37.6.3. Security & Defaults (77)
– SPECIAL FEAUTURE FOR INSTALLERS
Piccolo has the possibility of store the patch (for channels and fixtures) as default… In this case,
these patches can be recovered automatically when Piccolo is reset. This function is useful for
installer of the lighting system. The function can be protected using a password. This way nobody
without the password can change it by mistake. In the menu:
Security
allows setting a
password
to protect the default patches. If the password is
ENABLED
it will not be possible to change the patches to factory default.
To store the Patches data: first edit the patches, and then with the
Saved
cell execute the
command
0:SAVE
(with
password
as
ENABLE
). After this the data is stored, set
Load
Summary of Contents for Piccolo 12