Piccolo
26 from 82
www.lt-light.com
To store the next cue with the current scene and
load it into a Submaster
[REC][LOAD][S#]
To load a groups range into consecutive Submasters
[GRP][#] [THRU][#][LOAD][S#]
To load a cues range into consecutives Submasters
[CUE][#][THRU][#][LOAD][LOAD][S#]
To load a group in any of these modes:
1:Absolute
or
2: Inhibit
[GRP][#][LOAD][LOAD][S#] or
[GRP][#][LOAD]]LOAD][LOAD][S#]
To load a cue in any of these modes:
4:Absolute
or
5: Inhibit
[CUE][#][LOAD]]LOAD][S#] or
[CUE][#][LOAD]]LOAD][LOAD][S#]
*The loading option of the LOAD window, also can be selected entered the index number (#) or using the encoder.
A cue/group loaded in
Normal
mode:
Each Submaster puts its content in scene in an independent way.
A cue/group loaded in
Absolute
mode:
The Submaster puts its content in scene at the same time it forces the output of the rest of the
masters to zero. The result is similar to the flash solo function, but with a change faded. Very
useful for curtains, etc…
A cue/group loaded in
Inhibit
mode:
The Submaster does not put the content on stage, if active, but it will take it out if content is active
from any Submasters or from the Crossfader. This function is useful in the event of unexpected
happenings on stage. For example, a moving light disturbing the scene can be inhibited (taken out)
quickly.
The scene output (levels) of all the Submasters are controlled by the grandmaster,
GM
, also it’s
controlled for the
SM
(this can be changed in the configuration menu 31), and its blackout key.
In monitor & display:
Submasters from 01 to 03 are loaded with groups and submasters from 04 to 10 are loaded with
cues, in different modes (normal, absolute –
A
- & inhibit –
I
-)
Summary of Contents for Piccolo 12
Page 1: ...USER MANUAL VERSION 2 06...
Page 2: ...Piccolo 2 from 82 www lt light com...
Page 82: ...Piccolo 82 from 82 www lt light com...