Connecting the Cables
60
4.6
Connecting Cables to the Power Terminal Block
Power supply cables must be connected to the R, S, and T terminals. Connecting power cables to
other terminals will damage the inverter.
Note
The motor will rotate in the opposite direction if the U, V, and W terminals are connected in a wrong
phase order.
4.6.1
0.75
–
22 kW (200 V/400 V)
Cable connection for utilizing the built-in dynamic braking unit
Connect the cables from the dynamic braking unit to the P (+) and B terminals to utilize the
built-in dynamic braking unit.
Terminal Symbol
Terminal Name
Description
R (L1), S (L2), T (L3)
AC power supply input
terminals
AC input terminals
P (+)
(+) DC voltage terminal
(+) DC link voltage terminal
N (-)
(-) DC voltage terminal
(-) DC link voltage terminal.
P (+), B
Dynamic brake resistor
terminals
Dynamic brake resistor terminals
U, V, W
Inverter output terminals
Output terminals to a 3-phase induction
motor