Safety Funtion STO(Safe Torque Off)
Safet
y
Funtio
n
ST
O
(Safe
To
rque
O
ff
)
227
10.2.4
Safety Function Terminal Description
24S
–
SE (SFT1)
24S
–
SP (SFT2)
SR + SR-
Short: Normal operation
Short: Normal operation
B Contact relay output
terminal
Open: Safety Trip (output
blockage )
Open: Safety Trip (output blockage)
10.2.5
Cable Specification for Signal Terminal Block Wiring
Terminal
Wire Thickness
Electrical Standard
Variety
Name
mm
2
AWG
24S
Safety Input power
0.33
–
1.25mm
2
(16
–
22 AWG)
Shield type
twisted-pair
wire
24 VDC, Max. 10 mA
SE
Safety Input 1 (SFT1)
Short: Safety function stop
(24S-SE or SP)
Open: Safety function operation
(24S-SP or SP)
SP
Safety Input 2 (SFT2)
SR+,SR-
Safety function completion
output relay
DC 24 V, 5 A below (B contact)
The length of the safety wiring at the input terminal must be less than 30 m.