Table of Functions
186
8.9
Parameter Mode
–
Auto Sequence Operation
Group (
AUT)
Auto Sequence Operation Group (PAR
AUT)
No.
Communi-
cation
Address
LCD Display Name
Setting Range
Initial
Value
Shift in
Opera-
tion
Control Mode
V
/
F
S
L
V
C
S
L
T
V
C
T
00 -
Jump Code Jump code
0-99
10
O
O O O X X
01 0h1901
Auto Mode Auto operation type
0 Auto-A
0:Auto-A X
O O O X X
1 Auto-B
02
Note
3
2)
0h1902
Auto Check Auto operation terminal
delay time
0.02
–
2.00 (sec)
0.10
X
O O O X X
03 0h1903
Seq Select
Sequence type selection 1
–
2
1
O
O O O X X
04
Note
33
)
0h1904
Step
Number 1
Number of sequence 1
steps
1
–
8
2
O
O O O X X
05
Note
3
4)
0h1905
Step
Number 2
Number of sequence 2
steps
1
–
8
2
O
O O O X X
10
Note
3
5)
0h190A
Seq 1/1 Freq 1/1 step frequency
0.01
–
maximum
frequency (Hz)
11.00
O
O O O X X
11 0h190B
Seq 1/1 XcelT 1/1 Acc/Dec time
0.1
–
600.0 (sec)
5.0
O
O O O X X
12 0h190C
Seq 1/1
SteadT
1/1 steady speed
operation time
0.1
–
600.0 (sec)
5.0
O
O O O X X
13 0h190D
Seq 1/1 Dir 1/1 operation direction 0 Reverse
1:Forward O
O O O X X
1 Forward
14 0h190E
Seq 1/2 Freq 1/2 step frequency
0.01
–
maximum
frequency (Hz)
21.00
O
O O O X X
15 0h190F
Seq 1/2 XcelT 1/2 Acc/Dec time
0.1
–
600.0 (sec)
5.0
O
O O O X X
16 0h1910
Seq 1/2
SteadT
1/2 steady speed
operation time
0.1
–
600.0 (sec)
5.0
O
O O O X X
17 0h1911
Seq 1/2 Dir 1/2 operation direction 0 Reverse
1:Forward O
O O O X X
1 Forward
18 0h190E
Seq 1/3 Freq 1/3 step frequency
0.01
–
maximum
frequency (Hz)
31.00
O
O O O X X
19 0h190F
Seq 1/3 XcelT 1/3 Acc/Dec time
0.1
–
600.0 (sec)
5.0
O
O O O X X
20 0h1910
Seq 1/3
SteadT
1/3 steady speed
operation time
0.1
–
600.0 (sec)
5.0
O
O O O X X
21 0h1915
Seq 1/3 Dir 1/3 operation direction 0 Reverse
1:Forward O
O O O X X
1 Forward
22 0h1906
Seq 1/4 Freq 1/4 step frequency
0.01
–
maximum
frequency (Hz)
41.00
O
O O O X X
23 0h1907
Seq 1/4 XcelT 1/4 Acc/Dec time
0.1
–
600.0 (sec)
5.0
O
O O O X X
24 0h1918
Seq 1/4
SteadT
1/4 steady speed
operation time
0.1
–
600.0 (sec)
5.0
O
O O O X X
25 0h1919
Seq 1/4 Dir 1/4 operation direction 0 Reverse
1:Forward O
O O O X X
1 Forward
26 0h191A
Seq 1/5 Freq 1/5 step frequency
0.01
–
maximum
frequency (Hz)
51.00
O
O O O X X
27 0h191B
Seq 1/5 XcelT 1/5 Acc/Dec time
0.1
–
600.0 (sec)
5.0
O
O O O X X
28 0h191C
Seq 1/5
SteadT
1/5 steady speed
operation time
0.1
–
600.0 (sec)
5.0
O
O O O X X
29 0h191D
Seq 1/5 Dir 1/5 operation direction 0 Reverse
1:Forward O
O O O X X
Summary of Contents for SV-iS7 series
Page 1: ......
Page 5: ......
Page 126: ...Basic Functions 115 Basic Functions Code Description V1 Quantizing ...
Page 223: ...212 Peripheral Devices Group 2 ...
Page 224: ...Peripheral Devices Peripheral Devices 213 Group 3 ...
Page 225: ...214 Peripheral Devices Group 4 ...
Page 231: ...220 Peripheral Devices TYPE 1 Maximum 400 Watts TYPE 2 Maximum 600 Watts ...
Page 255: ......