UNITOUR Power System
User Manual
Page 18
that alarm changes from red to yellow to signify that the alarm has been acknowledged. Tap
EXIT
.
The yellow acknowledged alarm allows any new alarms to be immediately brought to your
attention due to their red status.
You can set which conditions will activate an alarm. See section 3.21.2.
UNITOUR can also send SMS messages to relevant personnel if an alarm is detected. This
is a future feature.
2.1.1
UHM STATUS LED
•
Magenta = Booting up
•
Green = Good
•
Flashing Red = Alarm
•
Solid Red = UHM alarm
•
Yellow = Acknowledged alarm
2.1.2
Output Module LEDs
Comms LED
•
Green = Normal operation
•
Yellow = Error
Status LED
•
Green = Normal operation.
•
Flash Red = Input power fault. See section 2.1.4.
•
Yellow = Over temperature warning
•
Flashing Yellow = Software update in progress (Comms LED will be off)
•
Red = Over temperature shutdown
Channel LEDs
•
Blue = Dimmer mode. The intensity mimics the output level of the dimmer
•
Green = Switch mode. It is either On or Off to mimic the output state
•
Red Double Flash = The output circuit breaker has tripped
•
Red Single Flash = The input phase is out of voltage range or missing (every third
channel will be flashing because every third channel is powered by the same phase)
•
Orange Single Flash = The current warning (load or leakage) has been exceeded
•
Magenta = the channel has been selected for configuration or viewing
3
acknowledged
alarms
COMMS
STATUS
CHANNEL