UNITOUR Power System
User Manual
Page 29
View Currents Menu
•
Tap
LOAD (Amps)
to view the load current of every channel.
•
Tap
LEAKAGE (mA)
to view the earth leakage current of every channel.
Tap either
VIEW IS LIVE
or
VIEW IS PEAK
to toggle between views. “View is Live” displays
the real time RMS current value. “View is Peak” displays the highest value that has been
recorded since the peak reading was last reset.
You can set a warning level from 1% to 100% for each channels load current and a separate
warning level for its earth leakage current. If the warning level is reached or exceeded, the
value on the “Channel Currents” screen is displayed in yellow and an alarm is activated. See
“Configure Currents” below.
If a channel breaker trips, the display for that channel shows turns red and shows the load and
leakage currents that were present when the breaker tripped. This allows you to determine
the cause of the breaker tripping, either excess load current or excess leakage current.
Tap a
Channel
Button
to see detailed information about that channel including the times that
the peak load current and peak leakage current occurred. This can also assist you in
determining the cause of a tripped breaker.
Channels can also be selected by pressing their
CHANNEL SELECT
button located above
each channel’s circuit breaker on the front of the output modules.
Peak leakage
and the time
that it occurred
Peak load and
the time that it
occurred
Tap any channel
button to see
detailed information
about that channel