![background image](http://html1.mh-extra.com/html/ls/a2c-sg2-m12/a2c-sg2-m12_manual_1943703013.webp)
A2C-SG2-M12
WWW.LILLIESYSTEMS.COM
13 of 44
To parse all the parameters in the sensor to the A2C Import Utitlity program, press the Get Sensor Parameters
Figure 4 Get sensor parameters
If everything has been connected correctly, the parameters will be updated in the A2C Import Utility program.
Figure 5 ADC setup
To change a value, first change the value, followed by pressing the "Set Sensor Parameters" button. All the values changed will be
sent to the A2C-SG. To save the values, so that the A2C-SG uses the values at start up, press the "Program Sensor" button. If this
button is not press, the A2C-SG will use the previously saved values after a restart (power cycle).
To view real time measurement values, click on the "Measurements" tab. Next click the "Start Receiving" button.