10. Advanced functions
10-12
SV-iC5
Factory default of motor parameters (Function group 2)
H30-Motor
rating
[kW]
H32-Rated slip
freq
[Hz]
H33-Current
rating
[A]
H34-No-load
current
[A]
H42-Stator
resistance [
Ω
]
H44-Leakage
inductance
[mH]
0.2
0.9
0.5
3.0
14.0
122.0
0.4
1.8
1.1
3.0
6.7
61.58.893
0.75
3.5
2.1
2.33
2.46
28.14
1.5
6.5
3.5
2.33
1.13
14.75
2.2
8.8
4.4
2.0
0.869
11.31
10.10 Energy-saving operation
Group
LED Display
Parameter Name
Set
value
Min/Max
Range
Factory
Defaults
Unit
Function
group 1
F40
[Energy-saving level]
-
0/30
0
%
Set the amount of output voltage to be reduced in F40.
Set as the percent of Max output voltage.
For fan or pump applications, energy consumption can be dramatically reduced by decreasing the output
voltage when light or no load is connected.
10.11 Speed Search
Group
LED Display
Parameter Name
Set
value
Min/Max
Range
Factory
Defaults
Unit
Function
group 2
H22
[Speed Search Select]
-
0/15
0
H23
[Current level during Speed
search]
-
80/200
100
%
H24
[P gain during Speed search]
-
0/9999
100
H25
[I gain during speed search]
-
1000
I/O group
I54
[Multi-function
output
terminal select]
15
0/20
12
I55
[Multi-function relay select]
15
17
This is used to prevent possible fault from occurring if the inverter outputs the output voltage during operation
after the load is removed.
The inverter estimates the motor rpm based on output current, so detecting exact speed is difficult.
Current
Output
voltage
F40
Summary of Contents for SV iC5 Series
Page 8: ...Table of Contents viii SV iC5...
Page 22: ...3 Wiring 3 6 SV iC5 Notes...
Page 38: ...5 Programming keypad 5 14 SV iC5 Notes...
Page 42: ...6 Basic operation 6 4 SV iC5 Notes...
Page 64: ......
Page 68: ......
Page 108: ...10 Advanced functions 10 20 SV iC5 Notes...
Page 132: ...13 Troubleshooting Maintenance 13 6 SV iC5 Notes...
Page 136: ......
Page 142: ......
Page 143: ......