CHART DUAL FREQUENCY OPERATION
Sensitivity and Grayline
®
adjust differently when the Dual Frequency
feature is enabled. The LMS-350A lets you make changes to the
sensitivity and Grayline on
one side of the screen without
affecting the other. To adjust
the sensitivity, for example,
first press the SENS key. The
screen shown at right ap-
pears. To adjust the sensitiv-
ity for the left, or 50 kHz side
of the screen, press the key
adjacent to the "192kHz
50kHz" label. Now press the
left arrow key to decrease the
Dual Frequency, Split Screen Mode
(Left chart is operating at 50 kHz, right chart is
192 kHz.)
sensitivity or the right arrow to
increase it. When you're fin-
ished, press the CLR key to
erase the menus.
Note: If no frequency identification shows at the bottom of the screen, then
the 192 kHz frequency is in use. The letters "50 kHz" always show at the
bottom of the screen when the 50 kHz frequency is in use.
Remember, to use the 50 kHz frequency, you must have a 50 kHz
transducer attached to the unit. If you wish to use both 192 and 50 kHz
frequencies at the same time, you must have both transducers plus a
MY-2 adapter cable attached to the unit. See the transducer connec-
tions section at the front of this manual for more information.
Summary of Contents for LMS-350A
Page 1: ...INSTALLATION AND OPERATION INSTRUCTIONS LMS 350A ...
Page 4: ......
Page 49: ...45 GROUP H GROUP I GROUP M GROUP L GROUP O GROUP N GROUP K GROUP J ...
Page 50: ...46 GROUP P GROUP Q GROUP U GROUP T GROUP V GROUP S GROUP R ...
Page 52: ...48 WINDOW 13 WINDOW 12 WINDOW 15 WINDOW 14 WINDOW 11 WINDOW 10 WINDOW 9 WINDOW 8 ...
Page 53: ...49 WINDOW 21 WINDOW 20 WINDOW 19 WINDOW 18 WINDOW 17 WINDOW 16 ...
Page 92: ...89 This page intentionally left blank ...
Page 93: ...90 LITHO IN U S A 988 0133 01 ...