background image

21 

I600IGB03_19.docx 

DATA 

LOG* 

DESCRIZIONE 
DATA LOG 

DATA LOG 
DESCRIPTION 

INDICE 

MISURE* 

MEASURE 

INDEX* 

DESCRIZIONE 
MISURE 

MEASURE 
DESCRIPTION 

GRAFICO 

CHART 

 

M9 

Corrente Di Fase L3 

L3 Current 

 

M49 

Corrente Di Neutro 

N Current 

 

M101 

THD Corrente L1 

THD L1 Current 

 

M102 

THD Corrente L2 

THD L2 Current 

 

M103 

THD Corrente L3 

THD L3 Current 

 

M303 

Asimmetria Di Corrente 

Current Unbalance 

682 

Campion. 5s armoniche 

Harmonic 5s sampling time 

M120 

05 Armonica Tensione L1 

05 Harmonic L1 Voltage 

 

M121 

05 Armonica Tensione L2 

05 Harmonic L2 Voltage 

 

M122 

05 Armonica Tensione L3 

05 Harmonic L3 Voltage 

 

M126 

07 Armonica Tensione L1 

07 Harmonic L1 Voltage 

 

M127 

07 Armonica Tensione L2 

07 Harmonic L2 Voltage 

 

M128 

07 Armonica Tensione L3 

07 Harmonic L3 Voltage 

 

M138 

11 Armonica Tensione L1 

11 Harmonic L1 Voltage 

 

M139 

11 Armonica Tensione L2 

11 Harmonic L2 Voltage 

 

M140 

11 Armonica Tensione L3 

11 Harmonic L3 Voltage 

 

M144 

13 Armonica Tensione L1 

13 Harmonic L1 Voltage 

 

M145 

13 Armonica Tensione L2 

13 Harmonic L2 Voltage 

 

M146 

13 Armonica Tensione L3 

13 Harmonic L3 Voltage 

 

M220 

05 Armonica Corrente L1 

05 Harmonic L1 Current 

 

M221 

05 Armonica Corrente L2 

05 Harmonic L2 Current 

 

M222 

05 Armonica Corrente L3 

05 Harmonic L3 Current 

 

M226 

07 Armonica Corrente L1 

07 Harmonic L1 Current 

 

M227 

07 Armonica Corrente L2 

07 Harmonic L2 Current 

 

M228 

07 Armonica Corrente L3 

07 Harmonic L3 Current 

 

M238 

11 Armonica Corrente L1 

11 Harmonic L1 Current 

 

M239 

11 Armonica Corrente L2 

11 Harmonic L2 Current 

 

M240 

11 Armonica Corrente L3 

11 Harmonic L3 Current 

 

M244 

13 Armonica Corrente L1 

13 Harmonic L1 Current 

 

M245 

13 Armonica Corrente L2 

13 Harmonic L2 Current 

 

M246 

13 Armonica Corrente L3 

13 Harmonic L3 Current 

683 

SPI 

PI 

M5 

Tensione L1-L2 

L1-L2 Voltage 

 

M6 

Tensione L2-L3 

L2-L3 Voltage 

 

M10 

Tensione L3-L1 

L3-L1 Voltage 

 

M35 Frequenza 

Frequency 

 

M401 

Ingresso 1 

Input 1 

 

M402 

Ingresso 2 

Input 2 

 

M403 

Ingresso 3 

Input 3 

 

M404 

Ingresso 4 

Input 4 

 

M411 

Uscita 1 

Output 1 

 

M412 

Uscita 2 

Output 2 

 

M420 

OR allarmi 

OR alarm 

 

M1207 

Tensione L1L2 Massima 

High Voltage L1L2 

 

M1208 

Tensione L2L3 Massima 

High Voltage L2L3 

 

M1209 

Tensione L3L1 Massima 

High Voltage L3L1 

 

M1225 

Frequenza Massima 

High Frequency 

 

M1307 

Tensione L1L2 Minima 

Low Voltage L1L2 

 

M1308 

Tensione L2L3 Minima 

Low Voltage L2L3 

 

M1309 

Tensione L3L1 Minima 

Low Voltage L3L1 

 

M1325 

Frequenza Minima 

Low Frequency 

 

M2495 

Media mobile VL1-L2 

Mobile mean VL1-L2 

Summary of Contents for EXCCGLA01

Page 1: ...GATEWAY DATA LOGGER MODEM 2G 3G Operating manual Manuale operativo EXCGLA01 EXCGLAX1 I600IGB03_19 31100438...

Page 2: ...r EXCGLA01 in grado di raccogliere dati dai dispositivi in campo collegati tramite porta ethernet o seriale RS485 anche contemporaneamente Supporta i protocolli Modbus RTU ASCII e TCP I dati possono e...

Page 3: ...rnet e seriale RS485 per un totale massimo consentito di 31 unit Connections EXCGLA01 should be connected to a 24VDC power supply The devices in the field can be connected to both the ethernet and the...

Page 4: ...zo seriale nodo Si possono assegnare valori compresi tra quelli impostati nella sezione Canali vedere pi avanti Sulla porta ethernet il gateway data logger apre un servizio sulla porta 1000 che quindi...

Page 5: ...PS abilitato di fabbrica per l accesso all interfaccia web EXCGLA01 dotato di un certificato di protezione con firma automatica Quindi collegandosi viene visualizzato un messaggio di sicurezza Accetta...

Page 6: ...ation is possible for some of the models only ant it can take several minutes Mostra i data log in cui il dispositivo contenuto Goes to the data logs which the device is included in Modifica la defini...

Page 7: ...Data logs are data tables with timestamp information The data tables are defined in EXCGLA01 database and become automatically available according to the model of the device which has been recognized...

Page 8: ...basato Shows the data log which the chart is based on Canali I due canali fisici di comunicazione seriale RS485 e ethernet verso i dispositivi in campo sono descritti da alcuni parametri che possono e...

Page 9: ...azione System Some system information is shown i e memory availability No setup is required Data Ora Si accede a questo menu per modificare la data e l ora di riferimento per EXCGLA01 Queste informazi...

Page 10: ...bbrica admin Indirizzo server remoto l end point a cui inviare il file XML dei dati raccolti Nome utente e password credenziali per autenticarsi presso il server remoto all atto dell invio file Admini...

Page 11: ...ente pu scegliere La selezione viene fatta automaticamente da EXCGLA01 nel caso per il dispositivo aggiunto sia disponibile una sola scelta altrimenti l utente chiamato a indicare il gruppo di interes...

Page 12: ...GSM900 8 PSK Class E2 26dBm 3dB per DCS1800 e PCS1900 8 PSK Class 3 24dBm 1 7 3 7dB per UMTS 800 850 900 1900 21 Technical characteristics EXCGLA01 System resources CPU ARM Cortex A8 1 GHz Operating s...

Page 13: ...ETSI EN 301 489 1 ETSI EN 301 489 52 EN 301 511 ETSI EN 301 908 1 ETSI EN 301 908 2 EN 62311 EN 60950 1 Interface Antenna GSM UMTS antenna 50 SMA F Female connector SIM slot microSIM Environmental co...

Page 14: ...transfer switch 139 300 65 DCRG8 DCRG8F Rifasamento PFC 136 900 400 135 300 65 DMG DME PMVF Base Basic 568 60 10 569 300 35 571 86400 1500 570 900 400 DMG PMVF Base EXP EXM Basic EXP EXM 568 60 10 569...

Page 15: ...3_19 docx DISPOSITIVI DEVICES DESCRIZIONE DESCRIPTION DATA LOG TEMPO DI CAMPIONAMENTO SAMPLING TIME s GIORNI DI MEMORIA DAYS OF MEMORY DME CD Base Basic 578 900 400 579 86400 1500 LRD Base Basic 580 5...

Page 16: ...N M2015 Tensione L3 L1 GEN L3 L1 Voltage GEN M2054 Potenza attiva Equivalente GEN Eqv Active Power GEN 133 Motore Engine M2016 Tensione batteria Bettery voltage M2083 Ore di lavoro totali Total workin...

Page 17: ...in 10 days M7 Corrente Di Fase L1 L1 Current M8 Corrente Di Fase L2 L2 Current M9 Corrente Di Fase L3 L3 Current M11 Tensione Di Linea Equivalente Eqv Phase To Phase Voltage M13 Potenza Reattiva Equiv...

Page 18: ...ars M911 Ingresso Analogico 1 Analog Input 1 M912 Ingresso Analogico 2 Analog Input 2 575 Misure 15min 1 anno Measures 15min 1 year M901 Energia Attiva Importata L1 L1 Active Energy Import M906 Energi...

Page 19: ...ente L1 12 Harmonic L1 Current M242 12 Armonica Corrente L2 12 Harmonic L2 Current M243 12 Armonica Corrente L3 12 Harmonic L3 Current M244 13 Armonica Corrente L1 13 Harmonic L1 Current M245 13 Armon...

Page 20: ...M2378 Ingresso PLC 05 PLC input 05 M2379 Ingresso PLC 06 PLC input 06 M2380 Ingresso PLC 07 PLC input 07 M2381 Ingresso PLC 08 PLC input 08 M2410 Uscita PLC 01 PLC output 01 M2411 Uscita PLC 02 PLC ou...

Page 21: ...Harmonic L1 Current M221 05 Armonica Corrente L2 05 Harmonic L2 Current M222 05 Armonica Corrente L3 05 Harmonic L3 Current M226 07 Armonica Corrente L1 07 Harmonic L1 Current M227 07 Armonica Corrent...

Page 22: ...mero associato al data log e l indice delle misure sono i riferimenti da utilizzare qualora si volesse elaborare il file XML inviato da EXCGLA01 al server remoto Lo schema XSD disponibile sul sito int...

Reviews: