6
Electrical Installation Continued
•
There are several acceptable methods for connection of the electrical wires
to this product, the most common methods are described below and
illustrated in Figure 2.1, Figure 2.2, and Figure 2.3. An electrical pigtail
consisting of an electrical connector and wires are supplied with this unit.
The RED wire is the POSITIVE connection of the unit and the BLACK wire is
the NEGATIVE connection.
WARNING
NEVER ATTEMPT TO CONNECT AN ELECTRICAL POWER SOURCE
OTHER THAN 6-38V DC TO THIS PRODUCT, SERIOUS INJURY OR
DAMAGE CAN OCCUR IF THIS WARNING IS NOT FOLLOWED
•
Figure 2.1 shown below is the preferred and recommended method of
electrically connecting this product. This method utilizes a 30 Amp rated
automotive relay and allows the toggle switch to encounter only a fraction of
the overall current requirement.
Figure 2.1: Electrical diagram utilizing automotive relay.
7
Electrical Installation Continued
•
The electrical diagram shown below in Figure 2.2 is an acceptable
method for connection of this product; however, SPECIAL ATTENTION
MUST BE TAKEN TO ENSURE THE AMPERAGE RATING OF THE SWITCH
IS
GREATER
THAN THE MAXIMUM AMPERAGE SPECIFICATIONS OF
THE LIGHT. Amperage specifications of each light unit can be found
in the Specifications section of this manual under the Maximum
Amperage Requirement column in Table 3.1 on Page 9.
Figure 2.2: Electrical diagram utilizing toggle switch and fuse only.
Figure 2.3: Electrical diagram utilizing toggle switch and fuse only.
Copyright 2015 LOTTworx
Copyright 2015 LOTTworx