20
CODELOG CONFIGURABLE PARAMETERS
MONITOR MODE
1)Config (#1) 2)Start 3) Master FTable
1)Config
The SRX1200 allows the user to designate up to 8 configurable receiver
parameters that determine how the receiver will monitor frequencies of
interest and or how data will be collected. Configurations presents a
method for creating and storing recurrent project parameters, e.g.,
frequencies, scan cycle period, antenna scanning, noise blanking, gain,
used in a project. Parameters can be entered into the SRX1200 Host
software for upload to your SRX receiver.
The ability to pre-configure and store such parameters is also very useful
in the event receiver(s) will be used concurrently in several projects. A
user simply selects the corresponding number (1-8) to configure the
receiver to operate based on the parameters previously entered for use in
their project. It is recommended (for ease of entry) that all settings for a
configuration be initially set up through the SRX Host software, then
added to or amended through the receiver keypad.
2)Start
Initiates an automated scanning routine based on the preconfigured
parameters entered and for selected configuration (as described above).
While
auto-scanning
in ‘Monitor’
mode, the ‘
Setup/0
’ key
serves as a
‘Pause’ function
, to allow users to temporarily suspend scans
preconfigured scanning operations, Once stopped, the F up and F down
buttons will not enable travelling through the frequency table (as it is the
case in code-log), but will temporarily alter the frequency.while continuing
to monitor detections of interest. Pressing the
‘
Setup/0
’
key resumes the
preconfigured scanning operations.
CODELOG MODE
1)
NEW CFG
The ‘Config’ feature is further
described under
‘
Monitor Mode
’
on Page 18.
When a scan cycle is started Codelog or Monitor
mode, the receiver
applies and operates based on the defined parameters in the active
configuration. Data collected using the active configuration are saved to
the receiver’s flash memory. Some parameters
cannot be edited in the