R E C E I V E R O P E R A T I O N
Upon start-up, the following screen display is typically presented. This
screen is displayed when no-one is remotely logged on and the receiver is
in its idle (or SETUP) state.
Logging On
Logging on provides the ability to change the operational state of the
receiver. When a
valid ‘
log on
’
password is provided the receiver is
considered Online. If no password is provided (logged off) the receiver is
Offline. The differences between Online and Offline are described below:
Offline: the receiver allows read-only access, which means most inputs are
not allowed (unless a log on password is provided). The only allowed
input is the Reset Password function.
Online: the receiver allows full
write access
,
which means that all
functionality and input capabilities are available.
There are a few options for logging on. This is a good time to talk about
the arrow symbol circled in red, which will appear in the lower right of the
display anytime when there are more menu options than can be displayed
on a single view.
To access these extended displays, press the right arrow button, also
labelled
“ENTER”/. The left arrow button
labelled “BSPACE” will move
backwards to the previous display. The next display (as in example below)
shows the result of pressing the right arrow key. Note that there is still a
right arrow key displayed, meaning there are additional nested screen