Power Specification
Loring coffee roasters can be built to accommodate a wide range of electrical configurations. To
determine which Loring topology matches your facility’s supply, the customer should engage a
licensed electrician to perform a site survey, in order to provide the following information.
On the Product Specification Form, the customer has the option to choose among some commonly
occurring configurations. However, the customer should NOT approximate by choosing the closest one
if it is not an exact match.
If the customer site is not represented, contact Loring immediately for other possible configurations.
For example, a typical U.S. installation might be 208 VAC, 3-phase, at 60 Hz.
This equates to a specification of 208 (3P) - 60
A typical installation in Europe might be 400 VAC, 3-phase, at 50 Hz.
This equates to a specification of 400 (3P) - 50
Supply Voltage Combinations
Power
Voltage:
200 (3P)
208 (1P)
208 (3P)
220 (3P)
230 (3P)
240 (1P)
240 (3P)
380 (3P)
400 (3P)
415 (3P)
480 (3P)
–
–
–
Power
Frequency:
50 - 50Hz
60 - 60 Hz
Model
Number:
Eg. S15
Gas Type:
NG - Natural Gas
LPG - Propane
Example: S15 - NG- 380 (3 P) - 50