Apply alarm signals to the signal input terminal at the rear panel to enable alarm recording.
*
*
*
Set the alarm recording mode and alarm recording period in the ALARM SETUP screen.
An index signal is automatically recorded when alarm recording begins.
If Buzzer is set to ON in the ALARM SETUP screen, the buzzer sounds during the alarm record period.
If another alarm signal is received by the SET terminal while the VCR is recording in the alarm mode, it will not trigger a new
alarm recording.
NOTE:
The buzzer can be turned off by pressing the CLEAR BUZZER OFF button once.
The alarm record mode can be turned off by holding the CLEAR BUZZER OFF button for 3 seconds.
*
*
*
Remote alarms can be configured to
sound a buzzer at the VCR by connecting
external alarm signals to the ALARM IN and GND
terminals.
*
6H, 18H and 30H record modes are available
for alarm record.
ALARM SET INPUT
NORMAL mode
ALARM mode
NORMAL mode
6H-960H
RECORDING
6H-960H
RECORDING
6H-30H
ALARM
RECORDING
GND IN OUT
IN OUT TRIG
OUT
TAPE
END
1SHOT
REC
ALARM
LINK
IN
OUT
MIC IN
AUDIO
IN
OUT
VIDEO
RS232C
RESET
ALARM SIGNAL
GROUND