TABLE OF CONTENTS
E 9
To access the configuration just press the top button.
The message
RELAY #1?
is displayed.
The top button (<YES>) provides access to its configuration, the bottom button (<NO>) jump to the relay 2 rubric.
For the threshold access setting, the message displayed is:
THRESHOLD?
For the activation/deactivation delays access setting the messages are:
ACTIVATION DELAY?
DEACTIVATION DELAY?
The top button (<YES>) provides access to the configuration of the parameter, the bottom button (<NO>) jump to the
next rubric. In the case of <YES> choice , the actual parameter value is displayed and blinks. The buttons (up/down)
permits to increment/decrement the value. The value is validated after a delay of 4 seconds when no buttons is pressed.
For relay 2, the configuration procedure is the same as for relay 1.
The default detection factory settings for the 2 relays are:
- Threshold = 50 V, activation delay = 1 s deactivation delay = 1 s.