background image

E 2  

LOREME

 12, rue des Potiers d'Etain - 57071 Metz  

 03.87.76.32.51 - Email: [email protected] - [email protected]

 

 
Table of contents 

DEVICE PRESENTATION  .........................................................................................................................................  p3

 

 

OPERATING  ..............................................................................................................................................................  p4

 

 
CONFIGURATION  .....................................................................................................................................................  p5 
 

1) Network  .......................................................................................................................................................  p5 

 

2) Nominal voltage  .........................................................................................................................................  p5 

 

3) Relay #1  ......................................................................................................................................................  p5

 

 

4) Relay #2  ......................................................................................................................................................  p6 

 

5) Alarm relays parameters  ...........................................................................................................................  p6 

 

 

5.1) Under voltage alarm  .....................................................................................................................  p6 

 

 

5.2) Overvoltage alarm  ........................................................................................................................  p6 

 

 

5.3) Phase asymmetry alarm  ..............................................................................................................  p6 

 

 

5.4) Under frequency alarm  ................................................................................................................  p6

 

 

 

5.5) Over frequency alarm  ...................................................................................................................  p7 

 

 

5.6) HOLD function  ..............................................................................................................................  p7 

 

6) Relay #3  ......................................................................................................................................................  p7 

 

7) Special functions  .......................................................................................................................................  p7 

 

8) Activation and deactivation delays chronograms  ..................................................................................  p7

 

 

9) RPL23uc features  .......................................................................................................................................  p8 

 

10) RPL23peak features .................................................................................................................................  p8 

 

11) RPL23Ho features  ....................................................................................................................................  p8

 

 

EMC CONSIDERATION  ...........................................................................................................................................  p10 
 

1) Introduction  ...............................................................................................................................................  p10 

 

2) Recommendation of use  ..........................................................................................................................  p10 

 

 

2.1) General remarks  ..........................................................................................................................  p10 

 

 

2.2) Power Supply  ...............................................................................................................................  p10 

 

 

2.3) Inputs / Outputs  ...........................................................................................................................  p10

 

 

WIRING ......................................................................................................................................................................  p11

 

 

Summary of Contents for RPL23

Page 1: ...Y LOREME 12 rue des Potiers d Etain Actipole BORNY B P 35014 57071 METZ CEDEX 3 Phone 03 87 76 32 51 Contact Commercial Loreme fr Technique Loreme fr Download manual at www loreme fr CONFIGURATION HAN...

Page 2: ...p6 5 1 Under voltage alarm p6 5 2 Overvoltage alarm p6 5 3 Phase asymmetry alarm p6 5 4 Under frequency alarm p6 5 5 Over frequency alarm p7 5 6 HOLD function p7 6 Relay 3 p7 7 Special functions p7 8...

Page 3: ...nction Fault indication by falling output relay Power supply voltage LED Faults LEDs phases sequence error under over voltage under over frequency phase failure Alphanumeric 4 digits display for measu...

Page 4: ...f Over V and Under V LEDs are off Phases order LED is off C1 T1 and or C2 T2 contacts are closed The L1 N RMS input voltage or the L1 L2 DC voltage is displayed In case of overvoltage over frequency A...

Page 5: ...morized 2 conditions are necessary to disable it Make disappear the default that caused the alarm Push the alarm acknowledge button bottom button A bip confirms the acknowledge 1 Network parameters Di...

Page 6: ...allows to move to the next rubric Displayed message THRESHOLD Threshold setting from 0 to 99 No to disable the overvoltage detection Note If the threshold is set to 99 they will be no overvoltage det...

Page 7: ...m button leaves the configuration The configurable parameters are the alarm activation and deactivation delays The relay is in alarm if the phase order is not correct and is out of alarm if the phase...

Page 8: ...To access the configuration just press the top button The message RELAY 1 is displayed The top button YES provides access to its configuration the bottom button NO jump to the relay 2 rubric For the t...

Page 9: ...CTIVATION DELAY DEACTIVATION DELAY The top button YES provides access to the configuration of the parameter the bottom button NO jump to the next rubric In the case of YES choice the actual parameter...

Page 10: ...relays thyristor power groups Do not get closer within fifty centimeters of a device with a transmitter walkie talkie of a power of 5 W be cause the latter can create a field with an intensity higher...

Page 11: ...Common relay contact T3 T2 T1 terminals Work relay contact L1 terminal Phase 1 voltage input L2 terminal Phase 2 voltage input L3 terminal Phase 3 voltage input N terminal Neutral input optional For a...

Reviews: