Messages
- 19 -
11.18
909.1550.1-08
14
Messages
14.1 Status messages
An error code is displayed in the 7 segment display
41 in event of an error.
After the message has been output, the
machine will only function to a limited ex-
tent; the error must be corrected as quickly
as possible.
The status message can be deleted by
pressing the control knob 56.
i
14.2 Error messages
An error code is displayed in the 7 segment display
41 in event of an error. Press any button to display
the sub-error (Sub-Code).
As long as there is an error code on display
welding is not possible.
i
Code
Note
Cause
Possible remedy
H08
Short-circuit
Short-circuit in the output circuit
Eliminate the short-circuit (pick up
electrode holder, ...)
H30
Configuration
Component group recognition faulty
Inform Service
H34
Fans
Fan current faulty
Inform Service
Tab. 5: Status messages
Code
Error
Cause
Possible remedy
E01
Excessive temperature
Duty cycle exceeded
Allow switched-on machine to cool
down for a few minutes.
Dust filter contaminated
Replace dust filter
E02
Overvoltage
Mains voltage too high
Check mains voltage
E04-1
Protective earth conductor
monitoring
Fault current to protective earth con-
ductor
Connect the welding earth lead
E06
Overvoltage secondary
Initial voltage too high
Inform Service
E07
EEPROM
Communication with EEPROM defec-
tive
Switch machine off and on again, ex-
ecute master reset
E09
Voltage detection
Voltage measuring system faulty
Inform Service
E12
Power section
Power section start-up faulty
Inform Service
E13
Temperature sensor
Temperature sensor not ready for
operation
Inform Service
E14
Supply voltage
internal supply voltage too low
Check mains voltages
E15
Current detection
Error during current measurement
Inform Service
E18
Overload protection
Safety switch device to protect elec-
trical components
Inform Service
E22
Mains undervoltage
Mains voltage on power unit is too
low
Check mains voltages
E25
Idle generator
Idle generator faulty
Inform Service
E30
Error configuration
Faulty or wrong pc-board, wrong
software system installed
Inform Service
E31
Communications fault
CAN bus communication faulty
Switch the equipment off and on again
E32
FPGA
FPGA faulty
Inform Service
E33
Power section
Power module not symmetrical
Inform Service
E34
Fans
Fan current faulty
Inform Service
E40
Polarity reverser
Polarity reverser faulty
Inform Service
E41
Phase monitor
Recognised missing mains phase
Check mains fuse and mains supply
Tab. 6: Error messages