Start-up
- 16 -
11.18
909.1550.1-08
Function lock
The Function lock can be activated or deactivated.
The function lock can only be switched on in an active
state. When the function lock is switched on, all but-
tons on the control knob are blocked.
Function lock activation / deactivation
Â
Press button 55 to call up the secondary parameters.
Â
Select the Function lock secondary parameter (Code
"LOC") by rotating the control knob 56.
Â
Confirm the secondary parameter by pressing the
control knob 56.
Â
Set the desired value by rotating the control knob 56.
– "On " = Activated
– "OFF" = Deactivated
Â
Confirm the setting by pressing the control knob 56.
Switching the Function lock on / off
Â
Press the control knob 56 for at least 3 seconds.
9
"---" is briefly displayed in the 7 segment display 41
as confirmation.
9
All buttons on the control knob are blocked. If it is
operated, "---" is displayed.
The control knob 56 must be pressed again for at
least 3 seconds in order to disable the function lock.
The function lock setting is saved! If the
machine is switched off with the function
lock activated, the control panel is still
blocked when the machine is switched
back on.
MMA only (BasicPlus)
With this parameter the welding mode can be limited
to MMA only.
Â
Press button 55 to call up the secondary parameters.
Â
Select the secondary parameter “MMA only” (Code
“Elo”) using the knob 56.
Â
Confirm the secondary parameter by pressing the
control knob 56.
Â
Set the desired value by rotating the control knob 56.
– “on” = Only the MMA modes basic/rutile/CEL can
be selected.
– “OFF” = All modes can be selected.
Â
Confirm the setting by pressing the control knob 56.
Standby mode (idle state)
Â
Press the control knob 56 and the button 55 simulta-
neously for at least 3 seconds.
9
The connecting sockets are de-energized. All LEDs
are turned off. "OFF" is displayed in the 7 segment
display 41.
Â
Press the control knob 56 and the button 55 simulta-
neously for at least 3 seconds to exit standby mode.
(See also chapter Remote control)
Software version (Control Pro)
Â
Press buttons 30 and 51 simultaneously for at least
3 seconds.
9
The software version will be displayed. (See second-
ary parameters)
Master reset
Warning! All personal settings will be
lost.
All welding and secondary parameters are
reset to their factory settings (master reset
function).
Â
Press buttons 31 and 50 simultaneously for at least 3
seconds. (Control Pro)
Â
Press buttons 31 and 50 simultaneously for at least 3
seconds. (Basic Plus)
9
The 7 segment display and the control panel indica-
tors light up briefly as confirmation.
12.6 Remote control (optional)
Manual remote control HR 33 PST
A manual remote control with polarity and standby switch
is available for the X series.
Â
Plug the remote control into the remote control con-
necting socket 7.
Â
Press button 55 to call up the secondary parameters.
Â
Select the Remote control secondary parameter
(Code "FrA") by rotating the control knob 56.
Â
Confirm the secondary parameter by pressing the
control knob 56.
Â
Set the value "On" by rotating the control knob 56.
Â
Confirm the setting by pressing the control knob 56.
Â
Exit the secondary parameters by pressing the Menu
button 55.
I %
100
0
60
61
62
Abb. 10: Manual remote control HR 33 PST
60
The welding current rotary switch
is used to set the welding current.
The rotary knob covers the setting range from
minimum (minimum welding current of the
i
i