Chapter 3 Operation IP6704A TDMoEthernet
Loop Telecommunication International, Inc.
22
3.5.
System Configuration
3.5.1.
Console Port
The console port allows the user either to use a local VT-100 terminal or use a remote
VT-100 terminal via modem for system configuration, diagnostics, polling status reports,
etc. The console port Baud rate, data bit length, stop bit length, and parity bit length are
defaulted, as shown below.
Table 3-1 Console Port Setting
Item
Fixed Setting
Baud
9600
Data Length
8-Bits
Stop Bit
1-Bit
Parity
NONE
3.6.
Alarm
When the Loop-IP6704A reports an alarm condition, such as loss of synchronization, the
alarm will cause the LED on the front panel to light. Each alarm can be individually
enabled or disabled. The alarm types are listed in the table as below.
Table 3-2 Alarm Default
– for System and Line
Alarm
Option
Default
E1 Line
RAI
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
AIS
LOS
LOF
BPV
Alarm
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
Threshold
10E- (5, 6, 7, 8, 9)
10E-5
ES
Alarm
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
Threshold
1-900
1
UAS
Alarm
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
Threshold
1-900
1
E1
CSS
Alarm
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
Threshold
1-900
1
T1 Line
YEL
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
AIS
LOS
LOF
BPV
Alarm
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
Threshold
10E- (5, 6, 7, 8, 9)
10E-5
ES
Alarm
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
Threshold
1-900
1
UAS
Alarm
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
Threshold
1-900
1
T1
CSS
Alarm
DISABLE,CRITICAL,MINOR,MAJOR,INFO DISABLE
Threshold
1-900
1