E-16
Wiring for Gigabit Slide-in Module
Following are the summaries of cabling required:
Media
Speed
Wiring
10Mbps
Category 3,4,5 UTP/STP
100Mbps
Category 5 UTP/STP
Gigabit copper
1000Mbps
Category 5 UTP/STP
Gigabit Fiber SC
1000Mbps
62.5/125 or 50/125µm
multi-mode fiber optic
Console Port
The RS-232 console is an interface for connecting a terminal directly. Through
the console port, it provides rich diagnostic information includes network
statistics, link status and system setting. The operating mode of the console
port is:
DCE
9600 (Fix baud rate)
n (No parity checking)
8 (8 Data bits)
1 (1 stop bit)
None (No flow control)
You can use a normal RS-232 cable and connect to the console port on the device. After
the connection, you can run any terminal emulation program (Hyper Terminal,
Winterm, Telix, … and so on) to enter the startup screen of the device. All the detail
software operation, please refer to “Console port (out-of-band) connection” session of
chapter 5.