Operating Instructions
44
Copyright © Loma Systems
Original Document
4.8 Setting Up the Search Head
To set up the search head, proceed as follows:
1. Select Menus > Service > Configuration > Head to display the Head menu options which are
listed and described below
2. Use the Navigation Keys
to select each option in turn press the OK / Enter Key
to enable the value to be edited.
3. Use the Navigation Keys
to select the required option value and then press the
OK / Enter Key
to confirm the selection.
4. Repeat step 2 and 3 until you have selected and confirmed values for each option.
The Head menu options available are as follows:
Type
The 'Conveyor' option should be selected for the IQ3X search head.
Coil Gap
The coil gap required can be found on the serial number plate located within the control box of
the detector head. It is set at 0.6 times the smallest aperture dimension, which is generally the
aperture height.
Band
Frequency bands are used to prevent crosstalk between adjacent metal detectors that are
operating on the same frequency.
The options are OFF, or 1 through 10. If OFF is selected then all 70 frequencies, 31 through 937, will
be available for use for all products, making frequency selection and subsequent Learns a
manual process.
If a band number is selected then the 7 frequencies available in the band are used by the metal
detector when selecting the optimum inspection frequency for any product.
The available frequencies are banded as listed below, with all values shown in kHz:
l
Band 1: 31, 71, 109, 195, 224, 333 and 577
l
Band 2: 33, 73, 115, 197, 227, 349 and 600
l
Band 3: 35, 75, 121, 200, 234, 357 and 625
l
Band 4: 37, 77, 126, 203, 250, 366 and 652
l
Band 5: 39, 79, 130, 205, 254, 417 and 682
l
Band 6: 41, 81, 136, 208, 294, 441 and 714
l
Band 7: 43, 83, 142, 211, 300, 469 and 789
l
Band 8: 46, 85, 146, 214, 306, 484 and 833
l
Band 9: 48, 87, 152, 217, 319, 517 and 882
l
Band 10: 52, 89, 156, 221, 326, 536 and 937