background image

3.7 

Operation 

Notices

▲ Read Section §1 carefully before starting to use this equipment.
▲ Connect the ground wire with the machine directly.
▲ Ensure that the input is three phase: 50/60Hz, 380V-400V-440V ±10%.
▲ Before operation, none concerned people should not be around the working area and especially 

    children. Do not watch the arc in unprotected eyes.

▲ Ensure good ventilation of the machine to improve Duty Cycle.
▲ Turn off the engine when the operation finished for energy consumption efficiency.
▲ When power switch shuts off protectively because of failure. Don’t restart it until problem is resolved.

    Otherwise, the range of problem will be extended.

▲ In case of problems, contact your local dealer if no authorized maintenance staff is available!

Maintenance 

Troublesho-

oting

4.1 

Maintenance

In order to guarantee safe and proper operation of welding machines, they must be maintained 
regularly. Let customers understand the maintenance procedure of welding machines. Enable 
customers to carry on simple examination and inspections. Do your best to reduce the fault rate and 
repair times of welding machines to lengthen service life of arc welding machine. Maintenance items in 
detail are in the following table.

● Warning: For safety while maintaining the machine, please shut off the main input power and wait for 

   5 minutes, until capacitors voltage already drop to safe voltage 36V

 

 

Date 

Maintenance items

 

Daily 

examinati

on 

Observe that the knobs and switches in the front and at the back of arc 

welding machine are flexible and put correctly in place.  If any knob has not 

been put correctly in place, please correct.  If you can't correct or fix the knob, 

please replace immediately;  

If any  

switch is not flexible or it can't be put correctly in place, please replace  

immediately.  Please get in touch with maintenance service department if there 

are no accessories. 

After turn-on power, watch/listen if the arc-welding  machine has shaking, 

whistle calling or peculiar smell.  If there is one of the above problems, find out 

the reason and clear it. If you can't find out the reason, please contact your local 

service repair station or distributor/agent .  

Observe that the display value of LED is intact. If the display number is  

not 

intact, please replace the damaged LED.  If it still doesn’t work, please maintain 

or replace the display PCB.  

Observe that the min/max values  

on  

LED agree with the set value. If there is 

any difference and it has affected the normal welding results, please adjust it. 

Check whether the fan is damaged and whether it is normal to rotate or 

control.  If the fan is damaged, please change immediately.  If the fan  does not 

rotate after the machine is overheated, observe if there is something blocking 

the blade.  If it is blocked, please clear the problem.  If the fan does not rotate 

after getting rid of the above problems, you can poke the blade by the rotation 

direction of fan. If the fan rotates normally, the start capacity should be 

replaced.  If not, change the fan.   

Observe whether the fast connector is loose or overheated. If  the arc- welding  

machine has the above problems, it should be fastened or changed.  

Observe whether the current output cable is damaged. If it is damaged, it 

should be insulated or changed.  

Monthly 

examinati

on 

Using the dry compressed air to clear the inside of arc welding machine. 

Especially for clearing up the dusts on radiator, main voltage transformer, 

inductors, IGBT modules, fast recover diodes, PCB’s, etc.  

Check the screws  

and bolts  

in the machine. If any is loose, please screw it 

tight.  If it is shaved, please replace. If it is rusty, please erase rust on all bolts to 

ensure it works well. 

Quarter- 

yearly 

examinati

on 

Check whether the actual current accords with the displaying value. If they did 

not accord, they should be regulated. The actual welding current value can be 

measured by and adjusted by plier-type ampere meter.  

Yearly 

examinati

on 

Measure the insulating impedance among the main circuit, PCB and case, if it 

below 1M

Ω

, insulation is thought to be damaged and need to change, and need 

to change or strengthen insulation.  

 

Summary of Contents for Grand Tig 400 ACDC Pulse

Page 1: ...RAND TIG 400 ACDC PULSE IMPORTANT Read this OPERATOR MANUAL together with PRESCRIPTION AND COMPLIANCE MANUAL before to use this equipment In case of loss one of two parts contact immediately your deal...

Page 2: ...n for MMA Welding 3 3 3 MMA Welding Troubleshooting 3 4 Installation Operation for TIG Welding 3 4 1 Set up installation for TIG Welding 3 4 2 Operation for TIG Welding 3 4 3 Remote current control 3...

Page 3: ...ring of the public supply system Consideration should be given to shielding the supply cable of permanently installed arc welding equipment in metallic conduit or equivalent Shielding should be electr...

Page 4: ...monitors the oxide and helps better cleaning during aluminum welding Dual digital display meters for accurate pre setting and feedback of welding parameters output Up Down Button Remote Control on tor...

Page 5: ...current will be cut off It can self protect and prolong the using life Double purposes AC inverter TIG MMA and DC inverter TIG MMA Excellent performance on Aluminium alloy carbon steel stainless steel...

Page 6: ...king principle of GRAND TIG is shown as the following figure Three phase 380V work frequency AC is rectified into DC then is converted to medium frequency AC by inverter device IGBT module after reduc...

Page 7: ...splayed is indicated by the LEDs beside the display Current A Saved Setting JOB Time S Percentage and Frequency Hz If left inactive for several seconds display will revert back to main welding current...

Page 8: ...rent to increase 0 is Arc Force off 10 is maximum Arc Force This is practically useful for electrode types that have a higher operating voltage requirement or joint types that require a short arc leng...

Page 9: ...available in AC welding mode 27 28 29 Adjusts the balance as a percentage between the forward and reverse current cycles when welding in AC output mode The reverse part of the AC cycle gives the clea...

Page 10: ...uired by rotating the control knob Once the program is accessed it will automatically load To return to normal parameter settings press the control knob again which will also load the selected program...

Page 11: ...ead work piece is connected to the negative socket this is known as DCEP However various electrodes require a different polarity for optimum results and careful attention should be paid to the polarit...

Page 12: ...wer supply Wrong mode selected Check the MMA selector switch is selected 2 Porosity small cavities or holes resulting from gas pockets in weld metal Arc length too long Shorten the arc length Work pie...

Page 13: ...oltage welding power cable connected to the appropriate position not to pick the wrong voltage NOTE Secure the gas cylinder in an upright position by chaining them to a stationary support to prevent f...

Page 14: ...connected 11 Be shorted with 10 The button of UP DOWN input 12 Not connected Not connected 3 4 4 Tig Welding Techniques TIG Welding Fusion Technique Manual TIG welding is often considered the most dif...

Page 15: ...rare metallic element used for manufacturing TIG welding electrodes The TIG process relies on tungsten s hardness and high temperature resistance to carry the welding current to the arc Tungsten has...

Page 16: ...ssibility of the point falling off into the weld pool Electrode Included Angle Taper DC Welding Tungsten electrodes for DC welding should be ground longitudinally and concentrically with diamond wheel...

Page 17: ...g Check that correct type of tungsten is being used Check the balance control is not set too high on the balance reduce to lower setting 2 Contaminated tungsten Touching tungsten into the weld pool Ke...

Page 18: ...meter on the front panel of the welding power supply flick twice to indicate the synchronization is successful and complete Synchronization has to accomplish in 10s after the display is blank 4 Switc...

Page 19: ...wanders during welding Poor gas flow Check and set the gas flow between 10 15 l min flow rate Incorrect arc length Lower torch so that the tungsten is off of the work piece 2 5mm Tungsten incorrect o...

Page 20: ...arm connection to 20k ohm remote control potentiometer 5 Zero ohm minimum connection to 20k ohm remote control potentiometer 6 Not connected 7 Not connected 8 Trigger Switch Input 9 Trigger Switch Inp...

Page 21: ...e calling or peculiar smell If there is one of the above problems find out the reason and clear it If you can t find out the reason please contact your local service repair station or distributor agen...

Page 22: ...tput The welding cable damaged Repair or change it The earth cable connected unstably Check the earth cable The welding cable is too long Use an appropriate welding cable There is oil or dust on the w...

Page 23: ...ow lamp thermal protection always on E09 Over heating Program in default Yellow lamp thermal protection always on Welding machine E10 Phase loss Yellow lamp thermal protection always on E11 No water Y...

Page 24: ...4 4 Electrical schematic drawing...

Page 25: ...LOKERMANN Srl Via Produzione 16 18 37044 Cologna Veneta VR Italy Tel 39 0442 1722469 lokermann lokermann eu www lokermann eu...

Reviews: