SECTION 1— GENERAL INFORMATION

1-1 General Description

The Logitek Ultra-VU is a bargraph type audio me-

ter featuring two tricolor LED bargraphs with clip indi-
cators. Two function buttons and several auxiliary
data indicators are also included on the front panel.

1-2 Electrical Specifications

Bargraphs per meter:

Two

Indicators per bargraph:

63

Normal Range:

-70 dB to 0 dB plus clip - digital

-50 dB to + 20 dB plus clip - analog

Fine Range:

.2 dB per segment around ref pt.

Reference Point:

-10,-12,-14,-16,-18 or -20 dB

Peak Markers:

8,9,10,12,14,16,18 dB above ref pt

Ballistics:

VU Mode

300 mS/20dB attack & release

PPM Mode

0 mS attack, 2.8S/24dB release

Peak Hold

0 mS attack, 2 or 5 Second hold

Max Hold

0 mS attack, pushbutton release

Image/Phase

4 Sec hold on max image

Clip Indicator:

trigger on 1 or 4 consecutive

clipped samples

Frequency Response:

Normal

+/-.1 dB 20 Hz - 20 KHz

Loudness Filter

58 dBSPL auditory curve

-40 dB 20 Hz, 0 dB 1250 Hz, -50 dB 20 KHz

Brightness control:

8 levels

Analog Input:

Sensitivity

-10 to +20 dBu for full scale

rear panel adjustable

Overload Level

+24 dBu

Impedance

40 Kohm balanced

Connector

3-pin XLR

Digital Input:

Formats

AES/EBU or S/PDIF

Impedance

110 Ohm (XLR)

75 Ohm (coax adapter)

Pass-through

2200 Ohm (XLR)

Termination

transformer balanced

AC Line Input Voltage:

50-60 Hz

105-129 VAC or

(switch settable)

220-240 VAC

Power Requirement:

UV1-(all), UDT-(all)

10 Watts

UV2-(all)

20 Watts

Dimensions:

1RU enclosure

19" W x 7" D x 1

3

4

H

Desk top enclosure

8

1

4

“ W x 9" D x 2

1

4

” H

1-3 Standards

The Ultra-VU meters are designed to conform to

the ballistic standards described in IEEE document
G.2.1.2/13, IEC document 268 and EBU document
3205-E. This ensures that the bargraph motion will
closely track other standard mechanical and elec-
tronic meters.

The one exception to these standards is the PPM

attack time. The Ultra-VU uses a true peak measure-
ment scheme that always displays the highest peak
of the input signal. The PPM standard specifies a
short averaging period for peak signals that keeps
sounds with durations too short to be heard well from
being displayed, no matter how loud they are. The de-
lay also allows mechanical meters to keep up with
fast changing inputs. Under most circumstances
there is no noticeable difference between true peak
and PPM peak readings. However, if you do need the
Ultra-VU to conform to the PPM peak standard then
please contact the Logitek factory for further informa-
tion.

1-4 Instrument Identification

The Ultra-VU is identified by a model number and

a three or four digit serial number. The model number
and serial number appear on a label on the back of
the unit near the power cord. All correspondence to
your Logitek dealer or to the Logitek factory should
refer to the model number and serial number.

1-5 Where to Find Help

Logitek customer service personnel are available

to help with any questions, comments or problems
you might have with the Ultra-VU meter, both during
and after the warranty period. Our hours of operation
are 8AM to 5PM central time. We may be contacted in
one of the following ways.

By Phone:

877-231-5870 (USA & Canada)

or 713-664-4470

By Fax:

713-664-4479

By Email:

[email protected]

By Mail:

Logitek Electronic Systems, Inc.

5622 Edgemoor Drive

Houston, Texas 77081

USA

** Ultra-VU Operation & Service Manual **

Page 4

Summary of Contents for ULTRA-VU

Page 1: ...ULTRA VU LED BARGRAPH AUDIO METER Operation Service Manual Logitek...

Page 2: ...ngineer decompile disassemble or cre ate derivative works from the software You may not create copies of the software This statement will be governed by the laws of the State of Texas U S A Logitek re...

Page 3: ...Resolution Mode 7 3 8 Auxiliary Data Display 7 3 9 Changing Display Brightness 7 3 10 CLIP indicator set point 7 3 11 Resetting the Program 7 SECTION 4 MAINTENANCE 4 1 General Information 8 4 2 Fuse 8...

Page 4: ...o the ballistic standards described in IEEE document G 2 1 2 13 IEC document 268 and EBU document 3205 E This ensures that the bargraph motion will closely track other standard mechanical and elec tro...

Page 5: ...er be operated if the ambient temperature is above 55 degrees C 131 degrees F 2 5 Connecting Mains Power Connect the meter to the power mains with the en closed power cord The unit is factory set for...

Page 6: ...tches 6 7 and 8 as shown Zero Reference Setting Sw6 Sw7 Sw8 dBs below full scale Up Up Up 10 dB Up Up Dn 12 dB Up Dn Up 14 dB Up Dn Dn 16 dB Dn Up Up 18 dB Dn Up Dn 20 dB Dn Dn Up 20 dB Dn Dn Dn 20 dB...

Page 7: ...single red segment that maintains the highest PPM reading for a user se lectable amount of time If the holding period expires before the PPM dot equals or exceeds the peak hold dot then the peak hold...

Page 8: ...e meter in one second inter vals This function is active even when the received data is invalid Sample Rate Data Display Label Meaning 32 0 32 000 Hz 1 44 0 44 056 Hz 1 44 1 44 100 Hz 1 47 9 47 952 Hz...

Page 9: ...may damage these devices 4 4 Access to Circuit Cards Access to the circuitry of the rackmount and half rack meters is accomplished by removing the six screws that attach the top cover The inside of t...

Page 10: ...irst powered up it may generate noise up to 70 dBFS until it undergoes a calibration cycle 4 7 Digital Dual Input Control Card LG 265 Power from input connector P4 is connected to voltage regulators I...

Page 11: ...ad pulse IC1 and IC2 drive the upper bargraph left chan nel IC3 and IC4 drive the lower bargraph right channel IC5 drives the scale indicator LEDs along the bottom edge of the display Avoid removing a...

Page 12: ...500 Connectors P1 3 pin large header locking PN MLSS156 3A J1 3 pin large socket PN CE156F20 3A J2 Power entry module fuse holder SR 6200 4115 Switches S1 Slide DPDT CK L202 121MS02QE Transformers T1...

Page 13: ...s J1 2 Female XLR NT NC3FK H J3 3 pin socket PN CE100F28 3A J4 3 pin large socket PN CE156F20 3A J6 7 10 pin dual row socket PN 050 010 455 P3 3 pin header PN MFSS100 3A P4 3 pin large header PN MFSS1...

Page 14: ...crystal CT MP122 Resistors R1 2200 R2 110 R3 75 R4 1000 R5 6 100K R7 8 100K 2 5 position bussed CT 770 61 R104 R9 10 20K 8 position isolated SMD CT 767163203G R11 12 10K Switches S 1 8 Dip switch blo...

Page 15: ...NMC1206Z5U104M50T C19 01uf AV 12065E103MATMA C20 21 1uf 35V tantalum AV TAP105K035HSB C22 01uf AV 12065E103MATMA C23 1 uf 50V ceramic SMD NC NMC1206Z5U104M50T C24 25 470pf 100V ceramic SMD AV 12061A47...

Page 16: ...Microchip Technology Inc Chandler AZ MM Maxim Sunnyvale CA MO Motorola Semiconductor Products Phoenix AZ MP Mepcopal San Diego CA MU Murata Electronics Smyrna GA NC NIC Components Corp North Amityvil...

Page 17: ...SECTION 7 Diagrams Page 17 Ultra VU Operation Service Manual...

Page 18: ...Ultra VU Operation Service Manual Page 18...

Page 19: ...Page 19 Ultra VU Operation Service Manual...

Page 20: ...Pin5 5VDC The Mode button momentarily connects Pins 1 2 The Peak Hold button momentarily connects pins 3 2 Connect pins 4 5 to display the analog input when a valid digital input is present automatic...

Page 21: ...Page 21 Ultra VU Operation Service Manual...

Page 22: ...Ultra VU Operation Service Manual Page 22 1 2 3 4 5 6 Connector P3 Pin2 Pin5 5VDC The Mode button momentarily connects Pins 1 2 The Peak Hold button momentarily connects pins 3 2...

Page 23: ...Page 23 Ultra VU Operation Service Manual...

Page 24: ...Ultra VU Operation Service Manual Page 24...

Page 25: ...Page 25 Ultra VU Operation Service Manual...

Page 26: ...Ultra VU Operation Service Manual Page 26...

Page 27: ...Page 27 Ultra VU Operation Service Manual...

Page 28: ...Ultra VU Operation Service Manual Page 28...

Page 29: ...Seller s obligation under this warranty shall be limited to such adjustment as Seller may ob tain from the original manufacturer This limited warranty is void if equipment is modi fied or repaired wit...

Reviews: