GAS TROUBLE SHOOTING GUIDE
In order for the pilot to light, there must be sufficient spark at the pilot hood. To
check this, do the following:
1
Make sure the Piezo igniter is securely grounded. (It grounds to the cabinet by
contact.) Tighten if needed.
2
Make sure the electrode wire is connected.
3
Make sure electrode wire connections are not close to any metal. (Spark can
jump from wire to the metal.)
4
Check the gap at the electrode tip to the canopy (1/8” approx.) – adjust if
needed.
5
Inspect ceramic around electrode for cracks. If cracks are present igniter will
not work and needs to be replaced (pilot assembly.)