INSTALLATION
CLEARANCE TO COMBUSTIBLES – FREE STANDER
This appliance may be installed only with clearances as shown in Diagram 4.
DO NOT combine clearances from one type of installation with another in order to
achieve closer clearances.
Measurements below are minimum distances to combustibles.
A
Side Wall to Unit:
75mm
B
Back Wall to Unit:
150mm
C
Back Wall to Flue Centerline:
250mm
D
Side Wall to Flue Centerline:
450mm
E
Side Wall to Unit:
75mm
F
Side Wall to Flue Centerline:
238mm
Minimum ceiling height from top of units is 600mm
HEARTH SIZE
The Logaire Maui needs to be installed on a non-combustible surface no smaller than
the minimum size of the freestander overall dimensions as per Diagram 4.
DIAGRAM 4