![LOGAIRE FIRES MAUI Installation And Operating Instructions Manual Download Page 33](http://html.mh-extra.com/html/logaire-fires/maui/maui_installation-and-operating-instructions-manual_1934377033.webp)
P:\Public\Spec Sheets\MAUI Gas Fire Indtructions.pdf
33
MAUI ZERO CLEARANCE
OPTIONAL FRESH AIR SUPPLY
An optional outside combustions air supply may be added as follows.
1. Connect an aluminium flex pipe from the outside to the fresh inlet on the left side
of the zero clearance shell. Be sure to use a proper exterior cover on the outside
end of the flex line.
GAS SUPPLY LINE
Only a qualified service person should install the gas supply line in accordance with
all local building codes. If allowed by local building codes, a listed flexible gas line
may be used. The gas line shall be piped to the lower right side of the zero clearance
shell (see figure 18 on page 37).
For information regarding pressure testing and inlet pressure please refer to your
Maui
Gas Stove Installation and Operating Instructions.
INSTALLATION OF MAUI
1. Insert the Maui into the zero clearance shell.
2. Slide the 100mm piece of B-vent pipe down into the exhaust collar of the Maui.
Fasten both ends of the flex pipe with clamps.
3.
To finish installation, please refer to your
Maui Vented Gas Stove Installation And
Operating Instructions.
NOTE:
When installing the top flashing, be sure that the deflectors
in the flashing slides into the flashing clips on the zero
clearance shell (‘G’ in figure 16 page 36)