76
ENG
Unlocking the keypad
If the keypad is locked (the pilot light associated
with the key lock sensor is on), holding down the
key lock.
Sensor
turns the key lock function off
and the pilot light goes off.
Residual heat for radiant heaters
While a temperature on the cook top glass
surface is above 65ºC, this condition will be
shown in the
associated display, by means of an “H”.
If the cook top is switched off, the residual heat
is shown by a static “H” in the display. If the cook
top is on, but the power level is 0, the associated
display will show alternately “H” and “0”.
Operating the timer
The timer is activated by pressing the timer keys
(+) or (-) up to the big central symbol
.
The timer value can be selected between 1 and
99 minutes, and can be modified at any time.
To cancel the operation of the timer, select a
timer value of <00> using the sensor (-), or switch
off the timer by pressing the corresponding
sensors (+) and (-) at the same time.
Heater on timer
This can be any of the touch-control heaters.
When the timer value runs out, the heater
associated with the timer switches off.
The heater associated with the timer can be can
be selected.
Selectable heater
The user can select the heater on which the
timer function is to operate. The
selection of a new heater disables the previous
selection in such a way that the timer only
operates on
one heater each time.
The heater must always be selected before the
time is set; otherwise, the timer will switch off.
If we take longer than 10 seconds to select the
heater, the timer will switch off.
If, after selecting the heater, the time is not
defined (T=00) in 10 sec., the timer switches off.
It is possible for the user to time a heater at
power 0 .
If the configuration permits Alarm-mode ,
instead select a heater , the user touches again
the timer in the heater selection periode, it goes
to minute-minder mode and at the end of time
will not switch-off any heater.
In Alarm-mode, the dot of the timer display
doesn’t light.
Indication of the heater on timer with “t” on the
heater display.
The touch control indicates the heater on which
the timer is operating. This indication consists
of a “t”
blinking with the power level in the display of
the heater., 5sec every 15 sec. Also if the user
changes the value of the timer, the “t” blinks.
This option reminds the user at all times that
the heater is on timer.
Indication of the heater on timer with Led
(small symbol
)
The touch control indicates the heater on which
the timer is operating. This indication consists
of a LED (small symbol
) next to the double
display of the heater on timer.
This option reminds the user at all times that
the heater is on timer.
Increasing the value of the timer
If the sensor (+) or (-) associated with the timer
is held down, the value increases/decreases
automatically.
This makes it possible to reach the desired
timer setting more quickly. From the tenth
consecutive increase/decrease of the timer
setting, the speed at which the value changes
increases.
Duration of the warning
When the time set on the timer has run out, a