I. System Overview
The lift/elevator system security is an important part for a hotel. With Locstar system, all
lift-card holders shall be subject to prior authorization from the system administrator.
When using the lift, different person will be allocated with different authority, to enter into
floors.
Customers need to swipe their card through lift reader, and the lift will take the customers
to the assigned floor, if the customers are allowed to enter more than 1 floors, then press
the specified floor button.
II. System Composition
The system is composed of the lock software, lift controller, encoder, lift card reader and
cards.
1. Lock software is used for issuing cards. (And lift controller function should be selected
via the system setting).
2. Lift controller is the key component of the lift control system. Each lift controller can be
used to manage a 8 or 16 floors lift, maximum 64 floors lift.
3. Temic/Mifare encoder function: used for issuing cards with different authorities.
4. Lift card reader function: read card information.
III. Technical Parameters
1. LS-DT301/311 lift card reader( For Temic lock system)
Use T5557 card to read information .Which produced by ATMEL .
Fit Locstar Temic Door Lock System.
Reading distance: less than 10CM.
Data storage: long-term .
Frequency of repetition: long-term.
Information capacity: 264bit.
Password figure: 32bit
Voltage for reader: 12V
Working temperature: -10
℃~
55
℃
Antistatic:
>