background image

                                 

电梯控制器用户手册

V2.0          V2.0 User Manual for Lift Controller

 

  3 

 

  8 

 

I. System Overview 

 

The lift/elevator system security is an important part for a hotel. With Locstar system, all 

lift-card holders shall be subject to prior authorization from the system administrator. 

When using the lift, different person will be allocated with different authority, to enter into 

floors. 

Customers need to swipe their card through lift reader, and the lift will take the customers 

to the assigned floor, if the customers are allowed to enter more than 1 floors, then press 

the specified floor button.   

 

 

 
II. System Composition   

The system is composed of the lock software, lift controller, encoder, lift card reader and 

cards. 

 

1. Lock software is used for issuing cards. (And lift controller function should be selected 

via the system setting).   

 

2. Lift controller is the key component of the lift control system. Each lift controller can be 

used to manage a 8 or 16 floors lift, maximum 64 floors lift.   

 

3. Temic/Mifare encoder function: used for issuing cards with different authorities.   

 

4. Lift card reader function: read card information.   

 

III. Technical Parameters   

1. LS-DT301/311 lift card reader( For Temic lock system) 

Use T5557 card to read information .Which produced by ATMEL . 

Fit Locstar Temic Door Lock System. 

Reading distance: less than 10CM. 

Data storage: long-term . 

Frequency of repetition: long-term. 

Information capacity: 264bit.                                                                                                       

Password figure: 32bit                                                                                                     

Voltage for reader: 12V 

Working temperature: -10

℃~

55

 

Antistatic: 

15000V 

                                                                                   

Summary of Contents for LS-DT301

Page 1: ...nual for LOCSTAR Lift Controller Applicable model LS DT301 311 503 513 K01 K02 K12 K13 Shenzhen Locstar Technology Co Ltd Please read the manual when installation Keep the manual properly for future reference ...

Page 2: ...ler 第 2 页 共 8 页 Table of Contents I System Overview 3 II System Composition 3 4 III Technical Parameters 4 IV Wiring Instruction for System Installation 5 V Lift Control Card reader Setting 6 VI Explanation of Card Authority 6 VII Working Procedure 6 ...

Page 3: ...ware lift controller encoder lift card reader and cards 1 Lock software is used for issuing cards And lift controller function should be selected via the system setting 2 Lift controller is the key component of the lift control system Each lift controller can be used to manage a 8 or 16 floors lift maximum 64 floors lift 3 Temic Mifare encoder function used for issuing cards with different authori...

Page 4: ...55 Antistatic 15000V 2 LS DTK01 lift controller Working voltage 24V Working temperature 10 55 Antistatic 15000V Floors to be controlled 1 16 floors LS DTK02 lift controller Working voltage 24V Working temperature 10 55 Antistatic 15000V Floors to be controlled 1 16 floors LS DTK12 lift controller Working voltage 24V Working temperature 10 55 Antistatic 15000V Floors to be controlled Floor 1 8 LS D...

Page 5: ...V 2 0 5 button on the first floor 24V power for lift controller RVV 2 0 5 12V power for lift reader RVV 2 0 5 3 After converting 110 240V to 24V 12V allow the power supply connected to the main board of lift controller 4 Wiring diagram for lift controller and lift Connect the wires of lift floor buttons to the corresponding binding posts on the main board The floor number on floor button should be...

Page 6: ...电梯控制器用户手册 V2 0 V2 0 User Manual for Lift Controller 第 6 页 共 8 页 Wiring Diagram of Lift Controller and lift Remark for the above lift control and lift wiring diagram each PCB controls 4 floors ...

Page 7: ...s A Directly touch the Cancel Authorization Card after one short sound and flash of blue light the authorization is cleared B Forced clearing open the outer cover of lift card reader press the reset switch within 10 seconds and touch Authorization card to the reader After a long sound authorization is cleared VI Explanation of Card Authority 1 Scope of lift to be controlled with building control m...

Page 8: ...ss any button within 5s the relay will automatically disconnect 5s later 2 Working procedure for floor control mode 1 After entering the lift swipe the card then press the proper button of floor For example a guest holds a 7th floor guest card after swiping card in the lift need to press 7th floor button Remark After the guest swipes the card the lift controller will activate the output relay that...

Reviews: