10
Low Battery Warning
All Code Lockout Mode
Return to previous step
Definitions
Components and tools
Master PIN Code:
The Master PIN code is used for programming and for feature settings. It must be registered prior
to programming the lock. The Master code will also operate (unlock/lock) the lock (Main Menu selection #1).
User PIN Code:
The User code operates the lock. Maximum number of user codes is 250 with network module;
without the network module, maximum is 25 user codes (Main Menu selection #2).
Volume Mode:
The volume setting for PIN code verification is set to low by default. Otherwise it can be set to High or
Silent (Main Menu selection #4).
Automatic Re-lock Time:
After a successful code entry and the unit unlocks, you can set your lock to automatically
re-lock after a default time of 30 seconds. The Automatic Re-lock function can be enabled or disabled (Main Menu
selection #3*1).
All Code Lockout Mode:
This feature is enabled by the Master PIN code. When enabled, it restricts all User PIN codes
(except the Master PIN code). When the unit is in Lockout mode, the red locked padlock will appear on the screen
when attempting to enter a PIN code (Main Menu Selection #6).
Inside Indicator Light:
Shows active status (Locked) of lock and can be enable or disabled in the Advanced Lock
Settings (Main menu selection #3*2).
Low Battery:
When battery power is low, the low battery icon will begin flashing. If battery power is completely lost,
use the key override.
One Touch Locking:
When the latch is retracted, touching the keypad will extend the bolt (during Automatic Re-lock
duration or when Automatic Re-lock is disabled).
Privacy Mode Button:
Pressing and holding the Privacy button (found below thumb turn) for a duration of four
beeps deactivates the keypad, and because it is set from the inside, provides a secure lock for the convenience of the
occupant(s). (Privacy Mode needs to be enabled from the Menu before using the button (#3, Option 4, 1 # Enable, ))
Wrong Code Entry Limit:
After a specified number of unsuccessful attempts at entering a PIN code the unit will shut
down and not allow operation. With no RF network enabled default is 5; 10 with RF network enabled.
Shutdown time:
The unit will shutdown for a default of sixty (60) seconds and not allow operation after the wrong
code entry limit has been met. When the unit is in Shutdown, the red locking symbol will be flashing.
Tamper Alert:
Audible alarm sounds if attempting to forcibly remove outside lock from door.
Network Module Setting:
With the optional network module installed, this setting becomes available through Main
Menu option #7 and allows the lock to connect with a network controller.
Previous:
While in menu mode, pressing the icon (above #3) cancels the current operation and returns the user to
the previous step.
Complete
Continue
Register
Continue
Complete
Delete
Enable
Disable
Default settings
Automatic Re-lock
Inside Indicator Light
One Touch Locking
Privacy Button Setting
Handing the Lock
Enable
Disable
Enable
Disable
Enable
Disable
Performs automatic handling
of the lock
Continue
Complete
High
Low