Lockwood Digital Deadbolt User Manual Download Page 10

10

   Low Battery Warning

   All Code Lockout Mode

     Return to previous step

Definitions

Components and tools

Master PIN Code:

 The Master PIN code is used for programming and for feature settings. It must be registered prior 

to programming the lock. The Master code will also operate (unlock/lock) the lock (Main Menu selection #1).

User PIN Code:

 The User code operates the lock. Maximum number of user codes is 250 with network module; 

without the network module, maximum is 25 user codes (Main Menu selection #2).

Volume Mode:

 The volume setting for PIN code verification is set to low by default. Otherwise it can be set to High or 

Silent (Main Menu selection #4).

Automatic Re-lock Time:

 After a successful code entry and the unit unlocks, you can set your lock to automatically 

re-lock after a default time of 30 seconds. The Automatic Re-lock function can be enabled or disabled (Main Menu 

selection #3*1).

All Code Lockout Mode:

 This feature is enabled by the Master PIN code. When enabled, it restricts all User PIN codes 

(except the Master PIN code). When the unit is in Lockout mode, the red locked padlock will appear on the screen 

when attempting to enter a PIN code (Main Menu Selection #6).

Inside Indicator Light: 

Shows active status (Locked) of lock and can be enable or disabled in the Advanced Lock 

Settings (Main menu selection #3*2).

Low Battery:

 When battery power is low, the low battery icon will begin flashing. If battery power is completely lost, 

use the key override.

One Touch Locking:

 When the latch is retracted, touching the keypad will extend the bolt (during Automatic Re-lock 

duration or when Automatic Re-lock is disabled).

Privacy Mode Button:

 Pressing and holding the Privacy button (found below thumb turn) for a duration of four 

beeps deactivates the keypad, and because it is set from the inside, provides a secure lock for the convenience of the 

occupant(s).  (Privacy Mode needs to be enabled from the Menu before using the button  (#3, Option 4,  1 # Enable, ))

Wrong Code Entry Limit:

 After a specified number of unsuccessful attempts at entering a PIN code the unit will shut 

down and not allow operation. With no RF network enabled default is 5; 10 with RF network enabled.

Shutdown time: 

The unit will shutdown for a default of sixty (60) seconds and not allow operation after the wrong 

code entry limit has been met. When the unit is in Shutdown, the red locking symbol will be flashing.

Tamper Alert: 

Audible alarm sounds if attempting to forcibly remove outside lock from door.

Network Module Setting:

 With the optional network module installed, this setting becomes available through Main 

Menu option #7 and allows the lock to connect with a network controller.

Previous:

 While in menu mode, pressing the icon (above #3) cancels the current operation and returns the user to 

the previous step.

Complete

Continue

Register 

Continue

Complete

Delete

Enable

Disable

Default settings

Automatic Re-lock

Inside Indicator Light

One Touch Locking

Privacy Button Setting

Handing the Lock

Enable

Disable

Enable

Disable

Enable

Disable

Performs automatic handling

of the lock

Continue

Complete

High

Low

Summary of Contents for Digital Deadbolt

Page 1: ...USER GUIDE Lockwood Keyless Wireless Digital Deadbolt KEYLESS WIRELESS DIGITAL DEADBOLT LKDDBW SC 0316...

Page 2: ......

Page 3: ...________________________________________________________10 Definitions __________________________________________________________________________________________10 Operation___________________________...

Page 4: ...to operate the equipment IMPORTANT The accuracy of the door preparation is critical for the proper functioning and security of this product Misalignment can cause premature wear and a lessening of se...

Page 5: ...ide Escutcheon Door Preparation Lock Installation 54mm hole saw 2 Phillips screwdriver 25 4mm spade bit 2 5mm drill bit Chisel hammer Components and tools INSTALLATION Installation Programming Guide I...

Page 6: ...Inside escutcheon 1 Loosen the screw Phillips 2 holding the battery cover The screw remains attached to battery cover 2 Slide the battery cover up and out note the two tabs at bottom of battery cover...

Page 7: ...aligned Hand tighten until snug Do not over tighten 1 Install bolt in door NOTE The bolt must be in a retracted unlocked position when installing the lockset Attach with 2 M4 x 25 4mm screws supplied...

Page 8: ...insert the inside escutcheon thumbturn should be vertical 8 Install and secure using 3 M4 x 8mm pan head screws through the inside escutcheon into the mounting plate Fig 8 IMPORTANT Before installing...

Page 9: ...sed in This Guide Press the indicated number Enter Master PIN code 4 8 digits in length Press the on the keypad to Enter or Accept entry Enter User PIN Can be 4 8 digits in length Press the Key to ent...

Page 10: ...ely lost use the key override One Touch Locking When the latch is retracted touching the keypad will extend the bolt during Automatic Re lock duration or when Automatic Re lock is disabled Privacy Mod...

Page 11: ...igit Master PIN code followed by the key Lock visually confirms PIN code selection announces Registered This initial step must be performed upon installation or after resetting the lock to factory def...

Page 12: ...e Menu mode enter number press the key to continue 3 Enter 2 followed by the key 4 Enter 1 followed by the key 5 Enter the User Number to be registered 1 25 followed by the key 6 Enter a 4 8 digit PIN...

Page 13: ...e Advanced Lock Settings Disable Enable Disable Enable Disable Performs automatic handling of the lock Continue Complete Network Module Setting High Low Silent Volume Setting Enable Disable All Code L...

Page 14: ...hese simple steps The old Z Wave ZigBee network controller must be set on the unpaired mode Repeat steps A and B above in the Digital Deadbolt to remove it from the old Z Wave ZigBee network The lock...

Page 15: ...followed in the Lockwood Wireless Digital Deadbolt to include it to the new Z wave ZigBee network NOTE Lockwood Wireless Digital Deadbolt has been tested successfully with some Z Wave ZigBee controll...

Page 16: ...With the door open extend and retract the bolt if it is smooth check the strike alignment Bolt does not extend or retract smoothly a Bolt and strike are misaligned see above b Check the backset of do...

Page 17: ...gister The Master PIN code must be registered prior to adding user codes PIN codes must consist of 4 to 8 digits to register The same PIN code cannot be used for multiple users Registration management...

Page 18: ...et button for a minimum of 3 seconds and then reinstall the batteries once the batteries are properly installed release the reset button All features should now be returned to factory default Upon res...

Page 19: ...he batteries must be removed prior to removing and or inserting the network module Remove battery cover Remove batteries Remove and or insert network module Reinstall batteries Use feature programming...

Page 20: ...to 20 users Location Door Number User Type User Name PIN Code User Type User Name PIN Code Master User 01 User 11 User 02 User 12 User 03 User 13 User 04 User 14 User 05 User 15 User 06 User 16 User...

Page 21: ...rade and industrial personnel locksmiths and security dealers ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience ASSA...

Reviews: