5.  Specifications   

 

Operating Voltage 

DC 12V

±

10%

 

User Capacity 

2000 

Card Reading Distance 

3-6 cm 

Active Current 

60mA 

Idle Current 

25±5 mA 

Lock Output Load 

Max 3A 

Alarm Output Load 

Max 20A 

Operating Temperature 

-45

℃~

60

 

Operating Humidity   

10%- 90% RH 

Waterproof 

Conforms to IP68 

Adjustable Door Relay time 

0 -99 seconds 

Adjustable Alarm Time 

0- 3 minutes 

Wiegand Interface 

Wiegand 26 bit 

Wiring Connections 

Electric Lock, Exit Button, External Alarm,External reader 

6.  Installation 

 

Remove the back cover from the keypad using the supplied special screw driver 

 

Drill 2 holes on the wall for the Self tapping screws and I hole for the cable 

 

Put the supplied rubber bungs to into the two holes 

 

Fix the back cover firmly on the wall with 2 Self tapping screws 

 

Thread the cable through the cable hole 

 

Attach the keypad to the back cover.

 

 

 

 

Summary of Contents for LS-N100

Page 1: ...LS S100 LS N100 Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit...

Page 2: ...t from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits To add...

Page 3: ...ncluding lock output current short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households...

Page 4: ...Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm External reader 6 Installation Remove the back cover from the keypad usi...

Page 5: ...nnected 12 V Yellow OPEN Exit button one end the other end connected GND Brown D_IN Magnetic switch one end the other end connected GND Red 12V 12V DC Regulated Power Input Black GND 12V DC Regulated...

Page 6: ...ry settings Please note only installer data is restored user data will not be affected 9 Anti Tamper Alarm The unit uses a LDR light dependent resistor as an anti tamper alarm If the keypad is removed...

Page 7: ...alid card only users Set valid card and PIN users Set valid card or PIN users 3 0 Entry is by card only 3 1 Entry is by card and PIN together 3 2 Entry is by either card or PIN default To add a user i...

Page 8: ...method a User ID is allocated to a card number Only one user ID can be allocated to the card number 1 ID number Card number User can be added continuously without exiting programming mode To delete a...

Page 9: ...rtake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 2 User ID To add a card user in card mode 3 0 To Add and Delete a card user The operating is...

Page 10: ...arm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute To disable door open detection Factory default 6 0 To enable door open detection 6...

Page 11: ...12 The unit operating as a Wiegand Output Reader In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit inp...

Reviews: