background image

 

10 

11.2   

Door Settings 

Relay Output Delay Time

 

To set door relay strike time 

 

Master code

 

#

 

  4      0

99      #

 

0-99 is to set the door relay time 0-99 seconds 

Door Open Detection   

Door  Open  Too  Long  (DOTL)  warning

.  When  used  with  an  optional  magnetic  contact  or  built-in 

magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside 

buzzer  will beep  automatically  to remind  people to close the door and continue  for 1 minute before 

switching off automatically. 

Door Forced Open warning. 

When used with an optional magnetic contact or built-in magnetic contact 

of the lock, if the door is forced open, or if the door is opened after 20 seconds ,the inside buzzer and 

alarm  output  will  both  operate.  The  Alarm  Output  time  is  adjustable  between  0-3  minutes  with  the 

default being 1 minute.

 

To  disable  door  open  detection.  (Factory 

default) 

  6      0      # 

To enable door open detection 

  6      1      # 

Alarm output time

 

To set the alarm output time (0-3 minutes) 

Factory default is 1 minute   

  5      0

3      #

 

Keypad Lockout & Alarm Output options

If there are 10 invalid cards or 10 incorrect PIN numbers 

in a 10 minute period either the keypad will lockout for 10 minutes or  both the alarm and the inside 

buzzer will operate for 10 minutes, depending on the option selected below.

 

Normal  status:  No  keypad  lockout  or 

alarm (factory default) 

  7      0      # (Factory default setting) 

Keypad Lockout 

  7      1      # 

Alarm and inside buzzer operate     

  7      2      # 

To remove the alarm

 

To reset the Door Forced Open warning 

Read valid card

 or 

Master Code # 

To reset the Door Open Too Long warning  Close the door 

or 

  Read valid card

 or 

Master Code # 

 

Summary of Contents for LS-N100

Page 1: ...LS S100 LS N100 Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit...

Page 2: ...t from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits To add...

Page 3: ...ncluding lock output current short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households...

Page 4: ...Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm External reader 6 Installation Remove the back cover from the keypad usi...

Page 5: ...nnected 12 V Yellow OPEN Exit button one end the other end connected GND Brown D_IN Magnetic switch one end the other end connected GND Red 12V 12V DC Regulated Power Input Black GND 12V DC Regulated...

Page 6: ...ry settings Please note only installer data is restored user data will not be affected 9 Anti Tamper Alarm The unit uses a LDR light dependent resistor as an anti tamper alarm If the keypad is removed...

Page 7: ...alid card only users Set valid card and PIN users Set valid card or PIN users 3 0 Entry is by card only 3 1 Entry is by card and PIN together 3 2 Entry is by either card or PIN default To add a user i...

Page 8: ...method a User ID is allocated to a card number Only one user ID can be allocated to the card number 1 ID number Card number User can be added continuously without exiting programming mode To delete a...

Page 9: ...rtake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 2 User ID To add a card user in card mode 3 0 To Add and Delete a card user The operating is...

Page 10: ...arm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute To disable door open detection Factory default 6 0 To enable door open detection 6...

Page 11: ...12 The unit operating as a Wiegand Output Reader In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit inp...

Reviews: