background image

 

 

 

1.  Packing List 

Name 

  Quantity 

Remarks 

Keypad 

      1 

 

User manual 

      1 

 

Screw driver   

      1 

Φ20mm×60mm,

Special for keypad

 

Rubber plug 

      2 

Φ6mm×30 mm, used for fixing 

Self tapping screws 

      2 

Φ4mm×28 mm, used for fixing 

Star screws

 

      1 

Φ3mm×6mm, used for fixing 

Please  ensure  that  all  the  above  contents  are  correct.  If  any  are  missing  please  notify  the 

supplier of the unit.   

2. Quick Reference Programming Guide

 

To enter the programming mode 

*    Master code    # 

999999 is the default factory master code   

To exit from the programming mode 

  *   

Note that to undertake the following programming the master user must be logged in 

To change the master code 

0    New code    #    New code    # 

The master code can be 6 to 8 digits   

To add a PIN user. 

 

1    User ID number    #    PIN #   

The  ID  number  is  any  number  between  1  &  2000.  The 

PIN  is  any  four  digits  between  0000  &  9999  with  the 

exception of 1234 which is reserved. Users can be added 

continuously without exiting programming mode 

To add a card user 

1    Read Card    # 

Cards  can  be  added  continuously  without  exiting 

programming mode 

To delete a PIN or a card user.   

2    User ID number    #    for a PIN user or       

2    Read Card    #    for a card user     

Users  can  be  deleted  continuously  without  exiting 

Summary of Contents for LS-N100

Page 1: ...LS S100 LS N100 Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit...

Page 2: ...t from the programming mode Note that to undertake the following programming the master user must be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits To add...

Page 3: ...ncluding lock output current short circuit protection Wiegand output and a backlit keypad These features make the unit an ideal choice for door access not only for small shops and domestic households...

Page 4: ...Adjustable Alarm Time 0 3 minutes Wiegand Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button External Alarm External reader 6 Installation Remove the back cover from the keypad usi...

Page 5: ...nnected 12 V Yellow OPEN Exit button one end the other end connected GND Brown D_IN Magnetic switch one end the other end connected GND Red 12V 12V DC Regulated Power Input Black GND 12V DC Regulated...

Page 6: ...ry settings Please note only installer data is restored user data will not be affected 9 Anti Tamper Alarm The unit uses a LDR light dependent resistor as an anti tamper alarm If the keypad is removed...

Page 7: ...alid card only users Set valid card and PIN users Set valid card or PIN users 3 0 Entry is by card only 3 1 Entry is by card and PIN together 3 2 Entry is by either card or PIN default To add a user i...

Page 8: ...method a User ID is allocated to a card number Only one user ID can be allocated to the card number 1 ID number Card number User can be added continuously without exiting programming mode To delete a...

Page 9: ...rtake this themselves ID number Old PIN New PIN New PIN To delete a Card and PIN user just delete the card 2 User ID To add a card user in card mode 3 0 To Add and Delete a card user The operating is...

Page 10: ...arm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute To disable door open detection Factory default 6 0 To enable door open detection 6...

Page 11: ...12 The unit operating as a Wiegand Output Reader In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit inp...

Reviews: