background image

Step8

Step7

   Place the unit on the base 
   panel and push it upward to
   the upper slot to complete.

Screw the unit tight.  

21

Lock Control - 

Kouterbaan 63 

 - 1840 Malderen - Belgium - Tel.  +32 52 57 43 02 - [email protected] - www.lockcontrol.be

Summary of Contents for ST-980 Series

Page 1: ...VER 13 11 21 ST 980 Series NETWORK PROXIMITY ACCESS CONTROL OPERATION AND INSTALLATION MANUAL Lock Control Kouterbaan 63 1840 Malderen Belgium Tel 32 52 57 43 02 info lockcontrol be www lockcontrol be...

Page 2: ...Operation instructions Turn on the unit Proximity Proximity and Password Door Opening Anti duress Setup Mode 5 Quick setting Delete Card Shunt Time Door Open Mode Change System Password Reader ID Numb...

Page 3: ...uency as the proximity unit around the neighborhood B In the area of a base station with radio or wireless transmission C On metal wall proximity distance will be shorten 5 It is suggested to separate...

Page 4: ...cal of A year B month C day to D year E month F day as effective in out time range Equipped with hardware self testing function Internal batteries will provide power supply when power cut occurred to...

Page 5: ...ound to complete deletion Press button to escape Completion of setting NO NO YES YES Check if power RED indicator is on Completion of setting Press button to exit setting mode Activate the software de...

Page 6: ...s 51L X 32W X 7 8H mm Ultrasonic connection waterproof shock proof Read range EM 125KHz 2 3 5cm Mifare 13 56MHz 1 5 2 5cm 12345678 SC 20 Thick card thickness of 1 78 mm ISO standard card dimensions Re...

Page 7: ...s code is 1 password is 1 2 3 4 then to activate anti duress alarm the user should key in 1 2 3 4 Note This function is only available for Door Open Mode 3 proximity and password mode Setup Mode User...

Page 8: ...card number manually or by proximity Press button after entering Registration completed one long beep sound Registration completed one long beep sound Repeated registration continuous beep sound Error...

Page 9: ...efault value as 2 Mode 2 Card proximity door open The door opens when the card is sensed Mode 3 Door open by proximity card and password The door opens by entering additional 4 digit password after se...

Page 10: ...nction selection Enter new system password 4 6 digits Press button after entering Confirm the new password Registration completed one long beep sound Error Continuous beep sound Back to the display sc...

Page 11: ...r 21 Enter system password Enter system password Nothing is entered Enter Back to system function selection Back to system function selection Setting completed one long beep sound occurred Error Conti...

Page 12: ...d Enter Back to system function selection Back to system function selection Setting completed one long beep sound occurred Setting completed one long beep sound occurred Error Continuous beep sound Er...

Page 13: ...Enter system password Nothing is entered Enter Back to system function selection Open door Setting completed one long beep sound occurred Error Continuous beep sound Back to the display screen 11 Lock...

Page 14: ...ore than 10m which may cause insufficient of the voltage Gray Yellow Purple Black Red Green White Blue Orange 1 Reader connector GND 12VDC P B R VIN GND NC DOOR COM NO P S NC COM N0 ALARM Y GR AP 55 R...

Page 15: ...O Connector B N C Connector Suitable for Fail safe electric lock such as electromagnetic lock Example Microcontroller Fail safe electric lock use of N O point to trigger Example Fail secure lock use...

Page 16: ...OM N0 ALARM Y GR Alarm power NC NO COM Eternal Relay Optional 5 Alarm wiring 3 Door detection wiring N C Reed Switch Orange Black Diode s white terminal DC12V 14 Lock Control Kouterbaan 63 1840 Malder...

Page 17: ...AY for high voltage or current to prevent any damage to the internal parts optional of AP 51 is available Examples of the wiring in this manual are for reference Please refer to the electric lock s ma...

Page 18: ...g on the PC board which may cause bad connection short circuit and interference to the system 3 How to disable anti tamper or duress alarm Solution Enter into the system setting mode or open the door...

Page 19: ...ep2 10 Installation of the unit Use attached screwdriver to unscrew the screws Separate the panel base from the unit Lock Control Kouterbaan 63 1840 Malderen Belgium Tel 32 52 57 43 02 info lockcontro...

Page 20: ...ernal RELAY please refer to the wiring diagram for wiring Insert both RELAY panel and wires into the door frame Screw the unit tight Place the unit on the base panel and push it upward to the upper sl...

Page 21: ...p2 Solid Door Use attached screwdriver to unscrew the screws Separate the panel base from the unit 19 Lock Control Kouterbaan 63 1840 Malderen Belgium Tel 32 52 57 43 02 info lockcontrol be www lockco...

Page 22: ...the wiring hole Connect RELAY and Pin wires complete Place the pin wires in the push button box Connect RELAY and Pin wires and complete other wirings Place all the pin wires in the push button box Pl...

Page 23: ...Place the unit on the base panel and push it upward to the upper slot to complete Screw the unit tight 21 Lock Control Kouterbaan 63 1840 Malderen Belgium Tel 32 52 57 43 02 info lockcontrol be www lo...