The Lochinvar Herald range is a floor standing gas fired condensing boiler. The equipment comprises a
stainless steel radial burner assembly and a heat exchanger that permits fully condensing operation.
The burner is initiated by a full electronic ignition sequence control that incorporates a spark ignition and a
flame rectification device for supervision of the flame.
The output from the boiler is regulated by a variable speed combustion fan and gas/air ratio controls to maintain
the correct combustion at all levels of modulation. This configuration allows modulation down to 20% of the
rated output.
For the correct operation of the boiler, it is essential that a suitably sized pump is utilised to maintain a constant
water flow rate through the heat exchanger. A suitable shunt pump is available as an ancillary option from
Lochinvar Ltd. See section 14.2.2
This equipment is intended for use on Group H Natural Gas (2
nd
Family) and LPG propane (3
rd
Family). The
information relating to propane firing is to be found in Section 18.0: LPG FUEL. This equipment MUST NOT
use gas other than that for which it has been designed and adjusted.
This equipment must be installed by a competent person, registered with a H.S.E. approved body. All
installations must conform to the relevant Gas Safety and Building Regulations. Health & Safety requirements
must also be taken into account when installing any equipment. Failure to comply with the above may lead to
prosecution.
If the equipment is to be connected to an unvented (pressurised) system, care must be taken to ensure all
extra safety requirements are satisfied should a high or low-pressure condition occur in the system.
The equipment is designed for direct connection to a flue system.
Ancillary Options:
Primary shunt Pumps
See section 14.2.2
DHW vessel sensor
LL200009A
Outside sensor for direct weather compensation of boiler
LL200010A
Con-X-Us Remote Monitoring App
LL100071724
Pressurisation Unit
o
Wall mounted – single pump
CHCWM1
o
Wall mounted – twin pump
CHCWM2
Condensate Neutralisation Kit
KIT2000
Low Velocity Header
Contact Lochinvar Limited
Flue System Components
See flue assemblies guide
Plate system separator
Contact Lochinvar Limited
ModBus Interface Module
LL100297842
BACnet Interface Module
LL100297828
Summary of Contents for HERALD HCB116CE
Page 8: ...8 3 1 2 PRINCIPLE PARTS TO BE USED IN CONJUNCTION WITH TABLE 3 1 1...
Page 31: ...31 Max distance between brackets...
Page 32: ...32...
Page 33: ...33...
Page 37: ...37...
Page 53: ...53 15 8 WIRING DIAGRAM 15 8 1 WIRING DIAGRAM...
Page 54: ...54 15 9 LADDER DIAGRAM 15 9 1 LADDER DIAGRAM...
Page 92: ...92...