30
Elapsed time
Total accumulated time the control system (water heater) has been
energized.
total heating time
Total accumulated time the control system has been in the heating
mode. IE: any heating elements have been energized.
Bank # Cycles
Total accumulated count of heating cycles for each Bank of heating elements.
Bank # on time
Total accumulated heating on time for each Bank of heating
elements.
CCB Version
Software version for Central Control Board.
uIM Version
Software version for User Interface Module.
CurrEnt fAuLt / ALErt MEnu
This menu displays non adjustable operational information. With the
Fault History sub menu selected in Main Menu; press the Operational
Button underneath “SELECT” to display the current Fault or Alert
message. If there is not a Fault or Alert condition currently active
“(none)” is displayed to the right of this menu.
Main Menu - Current fault selected
fAuLt hIstory MEnu
fault history Menu
This menu displays non adjustable operational information. The
control system records and stores the last 9 Fault and Alert
messages in chronological order in this menu. The most recent
will be at the top of the list. A time stamp is displayed below each
listed Fault and Alert message showing when the Fault or Alert
condition occurred.
The Fault History is useful when dealing with intermittent operational
problems or when the customer has reset the control system prior
to a service agent’s arrival.
With a Fault or Alert item selected press the Operational Button
underneath “VIEW” to display the details for the Fault or Alert
message. The Fault/Alert message screen displays a brief
description of the condition, contact information and access to the
Advanced service information sub menu.
Current / history fault Message
fAuLt oCCurrEnCE MEnu
Total accumulated number each individual Fault condition has
occurred is displayed in this menu. This running total of Fault
Occurrences can be useful in determining which (if any) operational
problems have been persistent.
fault occurrence Menu
rEstorE fACtory dEfAuLts MEnu
This control system menu allows the user to restore most of the
control system’s user settings to their factory default settings. User
settings in the Alarm Output Setup and Display Settings menus are
unaffected by executing Restore Factory Defaults.